1
2
3
Roof bearer
4
Solarflo - Solar Thermal Domestic Hot Water System
Note: Recommend
sealing hole with
silicon bead prior
to positioning
rubber seal
2.0
Installation of solar collector
2.5
FLAT roof Mounting system, parallel
1: Measure the mounting points (for suggested positions
see fig 5) and mount support bearers as recommended
in Section 2.2.
Dimension A = Recommended pitch of supports for
1 and 2 panel system
Dimension B = Recommended pitch of additional
support for 3 panel system
Dimension C = 1460mm (Front to back mounting
positions to give 45º panel inclination).
2: Drill fixing points into bearers using an 8mm diameter
drill (minimum depth 100mm).
3: Fasten bench screws into fixing points, minimum
screw depth > _ 100mm.
Attach rubber seal and tighten using M12 washer and
M12 nut.
Order:
- Bench screw
- Rubber seal
- M12 washer
- M12 nut
4: Assemble attachment brackets onto bench screws as
shown.
Order:
- M12 nut
- M12 washer
- Attachment bracket
- M12 washer
- M12 nut