Use 2" x 4" or thicker lumber for wood frame.
A. Outside width
B. Outside height
C. Depth
4. Apply wood preservative to the outside exposed surface.
5. Insert the frame in the wall opening. Square and level frame.
6. Attach frame securely to the wall.
Install Cabinet into Wood Frame
1. Remove top channel and both side channels using a
driver or socket wrench. Discard top channel and both side
channels.
A
A. Remove these screws
NOTE: Handle air conditioner carefully and gently.
1. Make sure the free end of the ground wire is outside of the
cabinet.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
10
A
B
C
" nut
A
A

Complete Installation

2. Insert cabinet into the framed wall opening. The top of the
cabinet should extend
trim, the cabinet should extend
A
A.
" (19.1 mm) extending into room
B. Trim
3. Use a level to check that cabinet is level side to side.
4. Check that air conditioner cabinet is tilted to the outside so
that water will run to the outside.
5. Reuse the insulation to seal opening between cabinet and
frame.
6. Use existing holes in sides and top of cabinet and 7 - #10 x
1" wood screws (not provided) to attach cabinet to frame.
NOTE: Do not overtighten screws or cabinet will distort and
provide a poor air seal between cabinet and air conditioner.
7. Caulk all outside wall openings around cabinet.
2. Insert air conditioner into cabinet.
A
A. Make sure the free end of the ground wire is outside of the cabinet.
A. Make sure the free end of the ground wire is outside of the cabinet.
" (19.1 mm) into the room. If there is
" (19.1 mm) past the trim.
B
A
A. Level
A