TABLE OF CONTENTS 1.0 WARRANTY INFORMATION Patton Electronics warrants all Model 2042 components to be SECTION PAGE free from defects, and will—at our option—repair or replace the prod- uct should it fail within one year from the first date of shipment. 1.0 Warranty Information ............2 This warranty is limited to defects in workmanship or materials, 1.1 Radio and TV Interference...
1.3 SERVICE 2.0 GENERAL INFORMATION All warranty and nonwarranty repairs must be returned freight pre- Thank you for your purchase of this Patton Electronics product. It paid and insured to Patton Electronics. All returns must have a Return has been thoroughly inspected and tested and is warranted for One Materials Authorization number on the outside of the shipping contain- Year for parts and labor.
3.0 CONFIGURATION 3.1 CONFIGURATION SWITCHES (MODEL 2042MC-MT) The Model 2042 is easy to install and is ruggedly designed for excellent reliability. The following instructions will help you set up and The Model 2042MC-MT has miniature DIP switches that you may install the Model 2042 properly.
3.2 CONFIGURATION SWITCHES (MODEL 2042MT-MC) 2042MC-MT DIP SWITCH SUMMARY TABLE Position Function Factory Default The Model 2042MT-MC has miniature DIP switches that you may Clock Source use to configure the units. Each Model 2042MT-MC is factory config- HSSI ST ured as DTE on the RS-530 end, and DCE on the HSSI end. Signal Clock Source Therefore, the RS-530 end “wants”...
4.0 INSTALLATION 2042MT-MC DIP SWITCH SUMMARY TABLE The Model 2042 is designed to connect RS-530 devices to Position Function Factory Default devices which employ the HSSI interface standard. This section Gapped Clock describes how to install the units. No Gapped Clock Gapped Clock 4.1 2042MC-MT CONNECTION...
5.0 OPERATION 4.3 AC POWER CONNECTION Once you have configured the Model 2042 properly (see Section The Model 2042 uses a 5VDC, 2A universal input, power supply 3.0) and have correctly connected DTE, DCE and power (see Section that is equipped with a male IEC-320 power entry connector and sup- 4.0), you are ready to operate the unit.
5.2.2 Remote Digital Loopback (RL) The Remote Loopback (RL) test checks the performance of the link between the DTE device and the DCE as well as the link between the local and remote DCE devices. Any characters sent from the DTE Model 2040MC-MT in this test mode will be sent to the local DCE, which will send the data to the remote DCE.
APPENDIX A APPENDIX B PATTON ELECTRONICS MODEL 2042 PATTON ELECTRONICS MODEL 2042 SPECIFICATIONS FACTORY REPLACEMENT PARTS AND ACCESSORIES Data Format: Synchronous Patton Model # Description Data Rate: 0 - 10Mbps 08055DCUI......100-240VAC (+5V ±5% reg. DC/2A) Universal Input Adapter Clocking: All HSSI co-directional timing patterns are supported. 0805EUR......European Power Cord CEE 7 0805UK ......United Kingdom Power Cord Standards:...
Page 10
APPENDIX C APPENDIX C PATTON ELECTRONICS MODEL 2042 PATTON ELECTRONICS MODEL 2042 HSSI INTERFACE RS-530 INTERFACE HD-50 Connector (DCE or DTE) DB-25 Connector Pin # Signal Pin # Signal FG (Frame Ground) SGND (Signal Ground) TD (Transmit Data) SGND (Signal Ground) RD (Receive Data) RT (Receive Timing-A) RTS (Request to Send)
Page 11
APPENDIX D APPENDIX E PATTON ELECTRONICS MODEL 2042MT-MC PATTON ELECTRONICS MODEL 2042MC-MT BLOCK DIAGRAM BLOCK DIAGRAM...