10. BEND the top half of the case as necessary to place it over the
strain relief assembly. Do not snap the case together yet.
11. Insert one captive screw through a saddle washer and then
insert the captive screw with the washer on it, through the hole in the
DB-25 end of the case. Snap that side of the case closed. Repeat the
process for the other side. This completes the cable installation
process.
4.1.2 TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45
The RJ-11 and RJ-45 connectors on the Model 2089's twisted pair
interface are pre-wired for a standard TELCO wiring environment. The
signal/pin relationships are shown below:
RJ-11
1 ...................GND
4 ...................XMT-
Connection to ground is optional
SIGNAL
(Continued)
12
RJ-45
SIGNAL
1 ...................N/C
2 ...................GND
3 ...................RCV-
5 ...................XMT-
6 ...................RCV+
7 ...................GND
8 ...................N/C