  • Page 1 TL-SG2216/TL-SG2424 Gigabit Smart Switch REV1.0.2 1910010666...
  • Page 2: Fcc Statement

    Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD.
  • Page 3: Safety Information

    Safety Information When product has power button, the power button is one of the way to shut off the product; When there is no power button, the only way to completely shut off power is to disconnect the product or the power adapter from the power source. Don’t disassemble the product, or make repairs yourself.
  • Page 4: Table Of Contents

    CONTENTS Package Contents ..........................1 Chapter 1 About this Guide......................2 Intended Readers ......................2 Conventions........................2 Overview of This Guide ....................2 Chapter 2 Introduction ........................5 Overview of the Switch ....................5 Main Features.......................5 Appearance Description ....................5 2.3.1 Front Panel ......................5 2.3.2 Rear Panel ......................6 Chapter 3 Login to the Switch.......................8 Login..........................8 Configuration ........................8...
  • Page 5 5.1.3 Port Security ....................25 5.1.4 Port Isolation ....................27 LAG ..........................28 5.2.1 LAG Table ......................28 5.2.2 Static LAG ......................29 Traffic Monitor ......................30 5.3.1 Traffic Summary....................30 5.3.2 Traffic Statistics ....................32 MAC Address......................33 5.4.1 Address Table ....................34 5.4.2 Static Address ....................35 5.4.3 Dynamic Address .....................36 5.4.4 Filtering Address ....................38 Chapter 6 VLAN..........................40...
  • Page 6 Multicast IP .........................79 8.2.1 Multicast IP Table .....................79 8.2.2 Static Multicast IP.....................80 Multicast Filter......................81 8.3.1 IP-Range......................82 8.3.2 Port Filter ......................82 Packet Statistics......................84 Chapter 9 QoS..........................86 DiffServ ........................89 9.1.1 Port Priority ......................89 9.1.2 Schedule Mode ....................90 9.1.3 802.1P Priority ....................91 9.1.4 DSCP Priority....................91 Bandwidth Control ......................93 9.2.1...
  • Page 7 11.3 Device Diagnose....................... 116 11.3.1 Cable Test ...................... 116 11.3.2 Loopback ....................... 117 11.4 Network Diagnose ....................117 11.4.1 Ping........................ 117 11.4.2 Tracert......................118 Appendix A: Specifications ......................120 Appendix B: Configuring the PCs ....................121 Appendix C: Glossary.........................123...
  • Page 8: Package Contents

    Package Contents The following items should be found in your box: One Gigabit Smart Switch One power cord Two mounting brackets and other fittings Installation Guide Resource CD for TL-SG2216/TL-SG2424 switch, including: • This User Guide • Other Helpful Information Note: Make sure that the package contains the above items.
  • Page 9: Chapter 1 About This Guide

    TL-SG2216/TL-SG2424 Gigabit Smart Switch without any explanation. Tips: The two devices of TL-SG2216 and TL-SG2424 are sharing this User Guide. For simplicity, we will take the operation on TL-SG2216 for example throughout the configuration chapters. TL-SG2216 and TL-SG2424 just differ in the number of LED indicators and ports and all figures in this guide are of TL-SG2216.
  • Page 10 Chapter Introduction Chapter 4 System This module is used to configure system properties of the switch. Here mainly introduces: System Info: Configure the description, system time and network parameters of the switch. User Manage: Configure the user name and password for users to log on to the Web management page with a certain access level.
  • Page 11 Chapter Introduction Chapter 9 QoS This module is used to configure QoS function to provide different quality of service for various network applications and requirements. Here mainly introduces: DiffServ: Configure priorities, port priority, 802.1P priority and DSCP priority. Bandwidth Control: Configure rate limit feature to control the traffic rate on each port;...
  • Page 12: Chapter 2 Introduction

    + Supports Telnet, CLI, SNMP v1/v2c/v3, RMON and web access. + Port Mirroring enables monitoring selected ingress/egress traffic. 2.3 Appearance Description 2.3.1 Front Panel The front panel of TL-SG2216 is shown as Figure 2-1. Figure 2-1 Front Panel of TL-SG2216...
  • Page 13: Rear Panel

    A device is connected to the corresponding port but no activity. Flashing Data is being transmitted or received. Link/Act No device is connected to the corresponding port. 2.3.2 Rear Panel The rear panel of TL-SG2216/TL-SG2424 features a power socket and a Grounding Terminal (marked with ).
  • Page 14 Figure 2-3 Rear Panel of TL-SG2216 Figure 2-4 Rear Panel of TL-SG2424 Grounding Terminal: TL-SG2216/TL-SG2424 already comes with Lightning Protection Mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable.
  • Page 15: Chapter 3 Login To The Switch

    Chapter 3 Login to the Switch 3.1 Login 1) To access the configuration utility, open a web-browser and type in the default address http://192.168.0.1 in the address field of the browser, then press the Enter key. Figure 3-1 Web-browser Tips: To log in to the switch, the IP address of your PC should be set in the same subnet addresses of the switch.
  • Page 16 Figure 3-3 Main Setup-Menu Note: Clicking Apply can only make the new configurations effective before the switch is rebooted. If you want to keep the configurations effective even the switch is rebooted, please click Saving Config. You are suggested to click Saving Config before cutting off the power or rebooting the switch to avoid losing the new configurations.
  • Page 17: Chapter 4 System

    Chapter 4 System The System module is mainly for system configuration of the switch, including four submenus: System Info, User Manage, System Tools and Access Security. 4.1 System Info The System Info, mainly for basic properties configuration, can be implemented on System Summary, Device Description, System Time, Daylight Saving Time and System IP pages.
  • Page 18 Indicates the SFP port is at the speed of 1000Mbps. Indicates the SFP port is at the speed of 100Mbps. When the cursor moves on the port, the detailed information of the port will be displayed. Figure 4-2 Port Information Port Info Port: Displays the port number of the switch.
  • Page 19: Device Description

    4.1.2 Device Description On this page you can configure the description of the switch, including device name, device location and system contact. Choose the menu System→System Info→Device Description to load the following page. Figure 4-4 Device Description The following entries are displayed on this screen: Device Description Device Name: Enter the name of the switch.
  • Page 20: Daylight Saving Time

    Time Config Manual: When this option is selected, you can set the date and time manually. Synchronize with When this option is selected, the administrator PC’s clock is PC’S Clock: utilized. Note: The system time will be restored to the default when the switch is restarted and you need to reconfigure the system time of the switch.
  • Page 21: System Ip

    Recurring Mode: Specify the DST configuration in recurring mode. This configuration is recurring in use. Offset: Specify the time adding in minutes when Daylight Saving Time comes. Start/End Time: Select starting time and ending time of Daylight Saving Time. Date Mode: Specify the DST configuration in Date mode.
  • Page 22: User Manage

    IP Address Mode: Select the mode to obtain IP Address for the switch. Static IP: When this option is selected, you should enter IP Address, Subnet Mask and Default Gateway manually. DHCP: When this option is selected, the switch will obtain network parameters from the DHCP Server.
  • Page 23: User Config

    Figure 4-8 User Table 4.2.2 User Config On this page you can configure the access level of the user to log on to the Web management page. The switch provides two access levels: Guest and Admin. The guest only can view the settings without the right to configure the switch;...
  • Page 24: System Tools

    Confirm Password: Retype the password. User Table Select: Select the desired entry to delete the corresponding user information. It is multi-optional The current user information can’t be deleted. User Name, Displays the current user ID, user name, access level and user Access Level and status.
  • Page 25: Config Backup

    4.3.3 Firmware Upgrade The switch system can be upgraded via the Web management page. To upgrade the system is to get more functions and better performance. Go to http://www.tp-link.com to download the updated firmware. Choose the menu System→System Tools→Firmware Upgrade to load the following page.
  • Page 26: System Reboot

    Figure 4-12 Firmware Upgrade Note: Don’t interrupt the upgrade. Please select the proper software version matching with your hardware to upgrade. To avoid damage, please don't turn off the device while upgrading. After upgrading, the device will reboot automatically. You are suggested to backup the configuration before upgrading. 4.3.4 System Reboot On this page you can reboot the switch and return to the login page.
  • Page 27: Access Security

    Figure 4-14 System Reset Note: After the system is reset, the switch will be reset to the default and all the settings will be cleared. 4.4 Access Security Access Security provides different security measures for the remote login so as to enhance the configuration management security.
  • Page 28 The following entries are displayed on this screen: Access Control Config Control Mode: Select the control mode for users to log on to the Web management page. IP-based: Select this option to limit the IP-range of the users for login. MAC-based: Select this option to limit the MAC Address of the users for login.
  • Page 29: Chapter 5 Switching

    Chapter 5 Switching Switching module is used to configure the basic functions of the switch, including four submenus: Port, LAG, Traffic Monitor and MAC Address. 5.1 Port The Port function, allowing you to configure the basic features for the port, is implemented on the Port Config, Port Mirror, Port Security and Port Isolation pages.
  • Page 30: Port Mirror

    Description: Give a description to the port for identification. Status: Allows you to Enable/Disable the port. When Enable is selected, the port can forward the packets normally. Speed and Duplex: Select the Speed and Duplex mode for the port. The device connected to the switch should be in the same Speed and Duplex mode with the switch.
  • Page 31 The following entries are displayed on this screen. Mirror Group List Group: Displays the mirror group number. Mirroring: Displays the mirroring port number. Mode: Displays the mirror mode. The value will be "Ingress" or "Egress". Mirrored Port: Displays the mirrored ports. Operation: Click Edit to configure the mirror group.
  • Page 32: Port Security

    Mirroring Port: Select the mirroring port number. Mirrored Port Port Select: Click the Select button to quick-select the corresponding port based on the port number you entered. Select: Select the desired port as a mirrored port. It is multi-optional. Port: Displays the port number.
  • Page 33 Figure 5-4 Port Security The following entries are displayed on this screen: Port Security Select: Select the desired port for Port Security configuration. It is multi-optional. Port: Displays the port number. Max Learned MAC: Specify the maximum number of MAC addresses that can be learned on the port.
  • Page 34: Port Isolation

    Note: The Port Security function is disabled for the LAG port member. Only the port is removed from the LAG, will the Port Security function be available for the port. 5.1.4 Port Isolation Port Isolation provides a method of restricting traffic flow to improve the network security by forbidding the port to forward packets to the ports that are not on its forward portlist.
  • Page 35: Lag

    5.2 LAG LAG (Link Aggregation Group) is to combine a number of ports together to make a single high-bandwidth data path, so as to implement the traffic load sharing among the member ports in the group and to enhance the connection reliability. For the member ports in an aggregation group, their basic configuration must be the same.
  • Page 36: Static Lag

    Global Config Hash Algorithm: Select the applied scope of Aggregate Arithmetic, which results in choosing a port to transfer the packets. • SRC MAC + DST MAC: When this option is selected, the Aggregate Arithmetic will apply to the source and destination MAC addresses of the packets.
  • Page 37: Traffic Monitor

    Figure 5-8 Manually Config The following entries are displayed on this screen: LAG Config Group Number: Select a Group Number for the LAG. Description: Give a description to the LAG for identification. Member Port Member Port: Select the port as the LAG member. Clearing all the ports of the LAG will delete this LAG.
  • Page 38 Figure 5-9 Traffic Summary The following entries are displayed on this screen: Auto Refresh Auto Refresh: Allows you to Enable/Disable refreshing the Traffic Summary automatically. Refresh Rate: Enter a value in seconds to specify the refresh interval. Traffic Summary Port Select: Click the Select button to quick-select the corresponding port based on the port number you entered.
  • Page 39: Traffic Statistics

    5.3.2 Traffic Statistics Traffic Statistics screen displays the detailed traffic information of each port, which facilitates you to monitor the traffic and locate faults promptly. Choose the menu Switching→Traffic Monitor→Traffic Statistics to load the following page. Figure 5-10 Traffic Statistics The following entries are displayed on this screen: Auto Refresh Auto Refresh:...
  • Page 40: Mac Address

    transmitted on the port. The error frames are not counted in. Alignment Errors: Displays the number of the received packets that have a bad Frame Check Sequence (FCS) with a non-integral octet (Alignment Error). The length of the packet is between 64 bytes and 1518 bytes.
  • Page 41: Address Table

    This function includes four submenus: Address Table, Static Address, Dynamic Address and Filtering Address. 5.4.1 Address Table On this page, you can view all the information of the Address Table. Choose the menu Switching→MAC Address→Address Table to load the following page. Figure 5-11 Address Table The following entries are displayed on this screen: Search Option...
  • Page 42: Static Address

    5.4.2 Static Address The static address table maintains the static address entries which can be added or removed manually, independent of the aging time. In the stable networks, the static MAC address entries can facilitate the switch to reduce broadcast packets and remarkably enhance the efficiency of packets forwarding without learning the address.
  • Page 43: Dynamic Address

    MAC Address: Displays the static MAC Address. VLAN ID: Displays the corresponding VLAN ID of the MAC address. Port: Displays the corresponding Port number of the MAC address. Here you can modify the port number to which the MAC address is bound. The new port should be in the same VLAN.
  • Page 44 Figure 5-13 Dynamic Address The following entries are displayed on this screen: Aging Config Auto Aging: Allows you to Enable/Disable the Auto Aging feature. Aging Time: Enter the Aging Time for the dynamic address. Search Option Search Option: Select a Search Option from the pull-down list and click the Search button to find your desired entry in the Dynamic Address Table.
  • Page 45: Filtering Address

    Tips: Setting aging time properly helps implement effective MAC address aging. The aging time that is too long or too short results decreases the performance of the switch. If the aging time is too long, excessive invalid MAC address entries maintained by the switch may fill up the MAC address table. This prevents the MAC address table from updating with network changes in time.
  • Page 46 Filtering Address Table Select: Select the entry to delete the corresponding filtering address. It is multi-optional. MAC Address: Displays the filtering MAC Address. VLAN ID: Displays the corresponding VLAN ID. Port: Here the symbol “__” indicates no specified port. Type: Displays the Type of the MAC address.
  • Page 47: Chapter 6 Vlan

    Chapter 6 VLAN The traditional Ethernet is a data network communication technology based on CSMA/CD (Carrier Sense Multiple Access/Collision Detect) via shared communication medium. Through the traditional Ethernet, the overfull hosts in LAN will result in serious collision, flooding broadcasts, poor performance or even breakdown of the Internet.
  • Page 48: Q Vlan

    6.1 802.1Q VLAN VLAN tags in the packets are necessary for the switch to identify packets of different VLANs. The switch works at the data link layer in OSI model and it can identify the data link layer encapsulation of the packet only, so you can add the VLAN tag field into the data link layer encapsulation for identification.
  • Page 49 (3) GENERAL: The GENERAL port can be added in multiple VLANs and set various egress rules according to the different VLANs. The default egress rule is UNTAG. The PVID can be set as the VID number of any VLAN the port belongs to. PVID PVID (Port Vlan ID) is the default VID of the port.
  • Page 50: Vlan Config

    6.1.1 VLAN Config On this page, you can view the current created 802.1Q VLAN. Choose the menu VLAN→802.1Q VLAN→VLAN Config to load the following page. Figure 6-3 VLAN Table To ensure the normal communication of the factory switch, the default VLAN of all ports is set to VLAN1.
  • Page 51 Figure 6-4 Create or Modify 802.1Q VLAN The following entries are displayed on this screen: VLAN Config VLAN ID: Enter the ID number of VLAN. Description: Give a description to the VLAN for identification. Check: Click the Check button to check whether the VLAN ID you entered is valid or not.
  • Page 52: Port Config

    Egress Rule: Select the Egress Rule for the VLAN port member. The default egress rule is UNTAG. • TAG: All packets forwarded by the port are tagged. The packets contain VLAN information. • UNTAG: Packets forwarded by the port are untagged. LAG: Displays the LAG to which the port belongs.
  • Page 53: Configuration Procedure

    Select the Link Type from the pull-down list for the port. Link Type: • ACCESS: The ACCESS port can be added in a single VLAN, and the egress rule of the port is UNTAG. The PVID is same as the current VLAN ID. If the current VLAN is deleted, the PVID will be set to 1 by default.
  • Page 54: Application Example For 802.1Q Vlan

    Modify/View VLAN. Optional. On the VLAN→802.1Q VLAN→VLAN Config page, click the Edit/Detail button to modify/view the information of the corresponding VLAN. Delete VLAN Optional. On the VLAN→802.1Q VLAN→VLAN Config page, select the desired entry to delete the corresponding VLAN by clicking the Delete button.
  • Page 55 Create VLAN10 Required. On VLAN→802.1Q VLAN→VLAN Config page, create a VLAN with its VLAN ID as 10, owning Port 2 and Port 3. Create VLAN20 Required. On VLAN→802.1Q VLAN→VLAN Config page, create a VLAN with its VLAN ID as 20, owning Port 3 and Port 4. Configure Switch B Step Operation...
  • Page 56: Chapter 7 Spanning Tree

    Chapter 7 Spanning Tree STP (Spanning Tree Protocol), subject to IEEE 802.1D standard, is to disbranch a ring network in the Data Link layer in a local network. Devices running STP discover loops in the network and block ports by exchanging information, in that way, a ring network can be disbranched to form a tree-topological ring-free network to prevent packets from being duplicated and forwarded endlessly in the network.
  • Page 57 Figure 7-1 Basic STP diagram STP Timers Hello Time: Hello Time ranges from 1 to 10 seconds. It specifies the interval to send BPDU packets. It is used to test the links. Max. Age: Max. Age ranges from 6 to 40 seconds. It specifies the maximum time the switch can wait without receiving a BPDU before attempting to reconfigure.
  • Page 58 Comparing BPDUs Each switch sends out configuration BPDUs and receives a configuration BPDU on one of its ports from another switch. The following table shows the comparing operations. Step Operation If the priority of the BPDU received on the port is lower than that of the BPDU if of the port itself, the switch discards the BPDU and does not change the BPDU of the port.
  • Page 59 RSTP (Rapid Spanning Tree Protocol), evolved from the 802.1D STP standard, enable Ethernet ports to transit their states rapidly. The premises for the port in the RSTP to transit its state rapidly are as follows. The condition for the root port to transit its port state rapidly: The old root port of the switch stops forwarding data and the designated port of the upstream switch begins to forward data.
  • Page 60 Figure 7-2 Basic MSTP diagram MSTP MSTP divides a network into several MST regions. The CST is generated between these MST regions, and multiple spanning trees can be generated in each MST region. Each spanning tree is called an instance. As well as STP, MSTP uses BPDUs to generate spanning tree. The only difference is that the BPDU for MSTP carries the MSTP configuration information on the switches.
  • Page 61: Stp Config

    Figure 7-3 Port roles The Spanning Tree module is mainly for spanning tree configuration of the switch, including four submenus: STP Config, Port Config, MSTP Instance and STP Security. 7.1 STP Config The STP Config function, for global configuration of spanning trees on the switch, can be implemented on STP Config and STP Summary pages.
  • Page 62 The following entries are displayed on this screen: Global Config STP: Select Enable/Disable STP function globally on the switch. Version: Select the desired STP version on the switch. STP: Spanning Tree Protocol. RSTP: Rapid Spanning Tree Protocol. MSTP: Multiple Spanning Tree Protocol. Parameters Config CIST Priority: Enter a value from 0 to 61440 to specify the priority of the switch...
  • Page 63: Stp Summary

    7.1.2 STP Summary On this page you can view the related parameters for Spanning Tree function. Choose the menu Spanning Tree→STP Config→STP Summary to load the following page. Figure 7-5 STP Summary 7.2 Port Config On this page you can configure the parameters of the ports for CIST Choose the menu Spanning Tree→Port Config to load the following page.
  • Page 64 Figure 7-6 Port Config The following entries are displayed on this screen: Port Config Port Select: Click the Select button to quick-select the corresponding port based on the port number you entered. Select: Select the desired port for STP configuration. It is multi-optional. Port: Displays the port number of the switch.
  • Page 65: Mstp Instance

    Port Role: Displays the role of the port played in the STP Instance. Root Port: Indicates the port that has the lowest path cost from this bridge to the Root Bridge and forwards packets to the root. Designated Port: Indicates the port that forwards packets to a downstream network segment or switch.
  • Page 66: Instance Config

    Figure 7-7 Region Config The following entries are displayed on this screen: Region Config Region Name: Create a name for MST region identification using up to 32 characters. Revision: Enter the revision from 0 to 65535 for MST region identification. 7.3.2 Instance Config Instance Configuration, a property of MST region, is used to describe the VLAN to Instance mapping configuration.
  • Page 67: Instance Port Config

    The following entries are displayed on this screen: Instance Table Instance ID Select: Click the Select button to quick-select the corresponding Instance ID based on the ID number you entered. Select: Select the desired Instance ID for configuration. It is multi-optional. Instance: Displays Instance ID of the switch.
  • Page 68 Figure 7-9 Instance Port Config The following entries are displayed on this screen: Port Config Instance ID: Select the desired instance ID for its port configuration. Port Select: Click the Select button to quick-select the corresponding port based on the port number you entered. Select: Select the desired port to specify its priority and path cost.
  • Page 69: Stp Security

    Global configuration Procedure for Spanning Tree function: Step Operation Description Make clear roles the switches Preparation. play spanning tree instances: root bridge designated bridge Globally configure MSTP Required. Enable Spanning Tree function on the switch parameters configure MSTP parameters Spanning Tree→STP Config→STP Config page.
  • Page 70 high-speed links may lead to low-speed links, and network congestion may occur. To avoid this, MSTP provides root protect function. Ports with this function enabled can only be set as designated ports in all spanning tree instances. When a port of this type receives BDPU packets with higher priority, it transits its state to blocking state and stops forwarding packets (as if it is disconnected from the link).
  • Page 71 Figure 7-10 Port Protect The following entries are displayed on this screen: Port Protect Port Select: Click the Select button to quick-select the corresponding port based on the port number you entered. Select: Select the desired port for port protect configuration. It is multi-optional.
  • Page 72: Tc Protect

    7.4.2 TC Protect When TC Protect is enabled for the port on Port Protect page, the TC threshold and TC protect cycle need to be configured on this page. Choose the menu Spanning Tree→STP Security→TC Protect to load the following page. Figure 7-11 TC Protect The following entries are displayed on this screen: TC Protect...
  • Page 73 On Spanning Tree→STP Config→Port Config page, enable MSTP function for the port. Configure the region name and Spanning Tree→MSTP Instance→Region the revision of MST region Config page, configure the region as TP-LINK and keep the default revision setting. Configure VLAN-to-Instance Spanning Tree→MSTP Instance→Instance...
  • Page 74 MSTP function for the port. Configure the region name and Spanning Tree→MSTP Instance→Region the revision of MST region Config page, configure the region as TP-LINK and keep the default revision setting. Configure VLAN-to-Instance On Spanning Tree→MSTP Instance→Instance mapping table of the MST region Config page, configure VLAN-to-Instance mapping table.
  • Page 75 The topology diagram of the two instances after the topology is stable For Instance 1 (VLAN101, 103 and 105), the red paths in the following figure are connected links; the gray paths are the blocked links. For Instance 2 (VLAN102, 104 and 106), the blue paths in the following figure are connected links;...
  • Page 76: Chapter 8 Multicast

    Chapter 8 Multicast Multicast Overview In the network, packets are sent in three modes: unicast, broadcast and multicast. In unicast, the source server sends separate copy information to each receiver. When a large number of users require this information, the server must send many pieces of information with the same content to the users.
  • Page 77 Multicast Address 1. Multicast IP Address: As specified by IANA (Internet Assigned Numbers Authority), Class D IP addresses are used as destination addresses of multicast packets. The multicast IP addresses range from 224.0.0.0~239.255.255.255. The following table displays the range and description of several special multicast IP addresses.
  • Page 78: Igmp Snooping

    IGMP Snooping In the network, the hosts apply to the near router for joining (leaving) a multicast group by sending IGMP (Internet Group Management Protocol) messages. When the up-stream device forwards down the multicast data, the switch is responsible for sending them to the hosts. IGMP Snooping is a multicast control mechanism, which can be used on the switch for dynamic registration of the multicast group.
  • Page 79: Snooping Config

    3. IGMP Leave Message The host, running IGMPv1, does not send IGMP leave message when leaving a multicast group, as a result, the switch can not get the leave information of the host momentarily. However, after leaving the multicast group, the host does not send IGMP report message any more, so the switch will remove the port from the corresponding multicast address table when its member port time times out.
  • Page 80: Port Config

    Figure 8-4 Basic Config The following entries are displayed on this screen: Global Config IGMP Snooping: Select Enable/Disable IGMP Snooping function globally on the switch. Unknown Multicast: Select the operation for the switch to process unknown multicast, Forward or Discard. IGMP Snooping Status Description: Displays IGMP Snooping status.
  • Page 81: Vlan Config

    Figure 8-5 Port Config The following entries are displayed on this screen: Port Config Port Select: Click the Select button to quick-select the corresponding port based on the port number you entered. Select: Select the desired port for IGMP Snooping feature configuration. It is multi-optional.
  • Page 82 Figure 8-6 VLAN Config The following entries are displayed on this screen: VLAN Config VLAN ID: Enter the VLAN ID to enable IGMP Snooping for the desired VLAN. Router Port Time: Specify the aging time of the router port. Within this time, if the switch doesn’t receive IGMP query message from the router port, it will consider this port is not a router port any more.
  • Page 83: Multicast Vlan

    Router Port Time: Displays the router port time of the VLAN. Member Port Time: Displays the member port time of the VLAN. Leave Time: Displays the leave time of the VLAN. Router Port: Displays the router port of the VLAN. Note: The settings here will be invalid when multicast VLAN is enabled Configuration procedure:...
  • Page 84 Figure 8-7 Multicast VLAN The following entries are displayed on this screen: Multicast VLAN Multicast VLAN: Select Enable/Disable Multicast VLAN feature. VLAN ID: Enter the VLAN ID of the multicast VLAN. Router Port Time: Specify the aging time of the router port. Within this time, if the switch doesn’t receive IGMP query message from the router port, it will consider this port is not a router port any more.
  • Page 85 Configuration procedure: Step Operation Description Enable IGMP Snooping Required. Enable IGMP Snooping globally on the switch port Multicast→IGMP function Snooping→Snooping Config and Port Config page. Create a multicast VLAN Required. Create a multicast VLAN and add all the member ports and router ports to the VLAN on the VLAN→802.1Q VLAN page.
  • Page 86: Multicast Ip

    Network Diagram Configuration Procedure Step Operation Description Create VLANs Create three VLANs with the VLAN ID 3, 4 and 5 respectively, and specify the description of VLAN3 as Multicast VLAN on VLAN→802.1Q VLAN page. Configure ports On VLAN→802.1Q VLAN function pages. For port 3, configure its link type as GENERAL and its egress rule as TAG, and add it to VLAN3, VLAN4 and VLAN5.
  • Page 87: Static Multicast Ip

    Choose the menu Multicast→Multicast IP→Multicast IP Table to load the following page. Figure 8-8 Multicast IP Table The following entries are displayed on this screen: Search Option Multicast IP: Enter the multicast IP address the desired entry must carry. VLAN ID: Enter the VLAN ID the desired entry must carry.
  • Page 88: Multicast Filter

    Figure 8-9 Static Multicast IP Table The following entries are displayed on this screen: Create Static Multicast Multicast IP: Enter static multicast IP address. VLAN ID: Enter the VLAN ID of the multicast IP. Forward Port: Enter the forward port of the multicast group. Search Option Search Option: Select the rules for displaying multicast IP table to find the desired...
  • Page 89: Ip-Range

    report message, the switch will firstly check the multicast filter rules configured for the receiving port. If the port can be added to the multicast group, it will be added to the multicast address table; if the port can not be added to the multicast group, the switch will drop the IGMP report message. In that way, the multicast streams will not be transmitted to this port, which allows you to control hosts joining the multicast group.
  • Page 90 function on the switch. Choose the menu Multicast→Multicast Filter→Port Filter to load the following page. Figure 8-11 Port Filter The following entries are displayed on this screen: Port Filter Config Port Select: Click the Select button to quick-select the corresponding port based on the port number you entered.
  • Page 91: Packet Statistics

    LAG: Displays the LAG number which the port belongs to. Note: Multicast Filter feature can only have effect on the VLAN with IGMP Snooping enabled. Multicast Filter feature has no effect on static multicast IP. Up to 5 IP-Ranges can be bound to one port. Configuration Procedure: Step Operation Description...
  • Page 92 Auto Refresh Auto Refresh: Select Enable/Disable auto refresh feature. Refresh Period: Enter the time from 3 to 300 in seconds to specify the auto refresh period. IGMP Statistics Port Select: Click the Select button to quick-select the corresponding port based on the port number you entered. Port: Displays the port number of the switch.
  • Page 93: Chapter 9 Qos

    Chapter 9 QoS QoS (Quality of Service) functions to provide different quality of service for various network applications and requirements and optimize the bandwidth resource distribution so as to provide a network service experience of a better quality. This switch classifies the ingress packets, maps the packets to different priority queues and then forwards the packets according to specified scheduling algorithms to implement QoS function.
  • Page 94 2. 802.1P Priority Figure 9-2 802.1Q frame As shown in the figure above, each 802.1Q Tag has a Pri field, comprising 3 bits. The 3-bit priority field is 802.1p priority in the range of 0 to 7. 802.1P priority determines the priority of the packets based on the Pri value.
  • Page 95 Figure 9-4 SP-Mode WRR-Mode: Weight Round Robin Mode. In this mode, packets in all the queues are sent in order based on the weight value for each queue and every queue can be assured of a certain service time. The weight value indicates the occupied proportion of the resource. WRR queue overcomes the disadvantage of SP queue that the packets in the queues with lower priority can not get service for a long time.
  • Page 96: Diffserv

    The QoS module is mainly for traffic control and priority configuration, including two submenus: DiffServ and Bandwidth Control. 9.1 DiffServ This switch classifies the ingress packets, maps the packets to different priority queues and then forwards the packets according to specified scheduling algorithms to implement QoS function. This switch implements three priority modes based on port, on 802.1P and on DSCP, and supports four queue scheduling algorithms.
  • Page 97: Schedule Mode

    Configuration Procedure: Step Operation Description Select the port priority Required. On QoS→DiffServ→Port Priority page, configure the port priority. Configure mapping Required. On QoS→DiffServ→802.1P Priority page, relation between the 802.1P configure the mapping relation between the 802.1P priority and TC priority and TC. Select a schedule mode Required.
  • Page 98: P Priority

    9.1.3 802.1P Priority On this page you can configure 802.1P priority. 802.1P gives the Pri field in 802.1Q tag a recommended definition. This field is used to divide packets into 8 priorities. When 802.1P Priority is enabled, the packets with 802.1Q tag are mapped to different priority levels based on 802.1P priority mode.
  • Page 99 Figure 9-9 DSCP Priority The following entries are displayed on this screen: DSCP Priority Config DSCP Priority: Select Enable or Disable DSCP Priority. Priority Level DSCP: Indicates the priority determined by the DS region of IP datagram. It ranges from 0 to 63. Priority: Indicates the 802.1P priority the packets with tag are mapped to.
  • Page 100: Bandwidth Control

    9.2 Bandwidth Control Bandwidth function, allowing you to control the traffic rate and broadcast flow on each port to ensure network in working order, can be implemented on Rate Limit and Storm Control pages. 9.2.1 Rate Limit Rate limit functions to control the ingress/egress traffic rate on each port via configuring the available bandwidth of each port.
  • Page 101: Storm Control

    Egress Rate(bps): Configure the bandwidth for sending packets on the port. You can select a rate from the dropdown list or select "Manual" to set Egress rate, the system will automatically select integral multiple of 64Kbps that closest to the rate you entered as the real Egress rate.
  • Page 102 The following entries are displayed on this screen: Storm Control Config Port Select: Click the Select button to quick-select the corresponding port based on the port number you entered. Select: Select the desired port for Storm Control configuration. It is multi-optional.
  • Page 103: Chapter 10 Snmp

    Chapter 10 SNMP SNMP Overview SNMP (Simple Network Management Protocol) has gained the most extensive application on the UDP/IP networks. SNMP provides a management frame to monitor and maintain the network devices. It is used for automatically managing the various network devices no matter the physical differences of the devices.
  • Page 104 SNMP v1: SNMP v1 adopts Community Name authentication. The community name is used to define the relation between SNMP Management Station and SNMP Agent. The SNMP packets failing to pass community name authentication are discarded. The community name can limit access to SNMP Agent from SNMP NMS, functioning as a password.
  • Page 105: Snmp Config

    management station. The specified User Name and the Auth/Privacy Password are used for SNMP Management Station to access the SNMP Agent, functioning as the password. SNMP module is used to configure the SNMP function of the switch, including three submenus: SNMP Config, Notification and RMON.
  • Page 106: Snmp View

    10.1.2 SNMP View The OID (Object Identifier) of the SNMP packets is used to describe the managed objects of the switch, and the MIB (Management Information Base) is the set of the OIDs. The SNMP View is created for the SNMP management station to manage MIB objects. Choose the menu SNMP→SNMP Config→SNMP View to load the following page.
  • Page 107 Choose the menu SNMP→SNMP Config→SNMP Group to load the following page. Figure 10-5 SNMP Group The following entries are displayed on this screen: Group Config Group Name: Enter the SNMP Group name. The Group Name, Security Model and Security Level compose the identifier of the SNMP Group. The Groups with these three items the same are considered to be the same.
  • Page 108: Snmp User

    Notify View: Select the View to be the Notify View. The management station can receive trap messages of the assigned SNMP view generated by the switch's SNMP agent. Group Table Select: Select the desired entry to delete the corresponding group. It is multi-optional.
  • Page 109: Snmp Community

    User Name: Enter the User Name here. User Type: Select the type for the User. • Local User: Indicates that the user is connected to a local SNMP engine. • Remote User: Indicates that the user is connected to a remote SNMP engine.
  • Page 110 SNMP v1 or SNMP v2c is employed, you can directly configure the SNMP Community on this page without configuring SNMP Group and User. Choose the menu SNMP→SNMP Config→SNMP Community to load the following page. Figure 10-7 SNMP Community The following entries are displayed on this screen: Community Config Community Name: Enter the Community Name here.
  • Page 111 Configuration Procedure: If SNMPv3 is employed, please take the following steps: Step Operation Description Enable SNMP function globally. Required. On the SNMP→SNMP Config→Global Config page, enable SNMP function globally. Create SNMP View. Required. On the SNMP→SNMP Config→SNMP View page, create SNMP View of the management agent.
  • Page 112: Notification

    10.2 Notification With the Notification function enabled, the switch can initiatively report to the management station about the important events that occur on the Views (e.g., the managed device is rebooted), which allows the management station to monitor and process the events in time. The notification information includes the following two types: Trap :...
  • Page 113: Rmon

    Type: Select the type for the notifications. • Trap: Indicates traps are sent. • Inform: Indicates informs are sent. The Inform type has a higher security than the Trap type. Retry: Specify the amount of times the switch resends an inform request.
  • Page 114: History Control

    RMON Group Function History Group After a history group is configured, the switch collects and records network statistics information periodically, based on which the management station can monitor network effectively. Event Group Event Group is used to define RMON events. Alarms occur when an event is detected.
  • Page 115: Event Config

    Status: Select Enable/Disable the corresponding sampling entry. 10.3.2 Event Config On this page, you can configure the RMON events. Choose the menu SNMP→RMON→Event Config to load the following page. Figure 10-10 Event Config The following entries are displayed on this screen: Event Table Select: Select the desired entry for configuration.
  • Page 116 Figure 10-11 Alarm Config The following entries are displayed on this screen: Alarm Table Select: Select the desired entry for configuration. Index: Displays the index number of the entry. Variable: Select the alarm variables from the pull-down list. Port: Select the port on which the Alarm entry acts. Sample Type: Specify the sampling method for the selected variable and comparing the value against the thresholds.
  • Page 117 Interval: Enter the alarm interval time in seconds. Owner: Enter the name of the device or user that defined the entry. Status: Select Enable/Disable the corresponding alarm entry. Note: When alarm variables exceed the Threshold on the same direction continuously for several times, an alarm event will only be generated on the first time, that is, the Rising Alarm and Falling Alarm are triggered alternately for that the alarm following to Rising Alarm is certainly a Falling Alarm and vice versa.
  • Page 118: Chapter 11 Maintenance

    Chapter 11 Maintenance Maintenance module, assembling the commonly used system tools to manage the switch, provides the convenient method to locate and solve the network problem. (1) System Monitor: Monitor the utilization status of the memory and the CPU of switch. (2)...
  • Page 119: Memory Monitor

    Click the Monitor button to enable the switch to monitor and display its CPU utilization rate every four seconds. 11.1.2 Memory Monitor Choose the menu Maintenance→System Monitor→Memory Monitor to load the following page. Figure 11-2 Memory Monitor Click the Monitor button to enable the switch to monitor and display its Memory utilization rate every four seconds.
  • Page 120: Log Table

    informational Informational messages debugging Debug-level messages Table 11-1 Log Level The Log function is implemented on the Log Table, Local Log, Remote Log and Backup Log pages. 11.2.1 Log Table The switch supports logs output to two directions, namely, log buffer and log file. The information in log buffer will be lost after the switch is rebooted or powered off whereas the information in log file will be kept effective even the switch is rebooted or powered off.
  • Page 121: Local Log

    11.2.2 Local Log Local Log is the log information saved in switch. By default, all system logs are saved in log buffer and the logs with severities from level_0 to level_4 are saved in log file meanwhile. On this page, you can set the output channel for logs.
  • Page 122: Backup Log

    Figure 11-5 Log Host The following entries are displayed on this screen: Log Host Index: Displays the index of the log host. The switch supports 4 log hosts. Host IP: Configure the IP for the log host. UDP Port: Displays the UDP port used for receiving/sending log information.
  • Page 123: Device Diagnose

    The following entry is displayed on this screen: Backup Log Backup Log: Click the Backup Log button to save the log as a file to your computer. Note: It will take a few minutes to backup the log file. Please wait without any operation. 11.3 Device Diagnose This switch provides Cable Test and Loopback functions for device diagnose.
  • Page 124: Loopback

    11.3.2 Loopback Loopback test function, looping the sender and the receiver of the signal, is used to test whether the port of the switch is available as well as to check and analyze the physical connection status of the port to help you locate and solve network malfunctions. Choose the menu Maintenance→Device Diagnose→Loopback to load the following page.
  • Page 125: Tracert

    Figure 11-9 Ping The following entries are displayed on this screen: Ping Config Destination IP: Enter the IP address of the destination node for Ping test. Ping Times: Enter the amount of times to send test data during Ping testing. The default value is recommended.
  • Page 126 The following entries are displayed on this screen: Tracert Config Destination IP: Enter the IP address of the destination device. Max Hop: Specify the maximum number of the route hops the test data can pass through. Return to CONTENTS...
  • Page 127: Appendix A: Specifications

    Appendix A: Specifications IEEE802.3 10Base-T Ethernet IEEE802.3u 100Base-TX/100Base-FX Fast Ethernet IEEE802.3ab 1000Base-T Gigabit Ethernet Standards IEEE802.3z 1000Base-X Gigabit Ethernet IEEE802.3x Flow Control IEEE802.1p QoS IEEE802.1q VLAN Ethernet: 10Mbps HD,20Mbps FD Transmission Rate Fast Ethernet: 100Mbps HD,200Mbps FD Gigabit Ethernet: 2000Mbps FD 10Base-T: UTP/STP of Cat.
  • Page 128: Appendix B: Configuring The Pcs

    Appendix B: Configuring the PCs In this section, we’ll introduce how to install and configure the TCP/IP correctly in Windows 2000. First make sure your Ethernet Adapter is working, refer to the adapter’s manual if necessary. On the Windows taskbar, click the Start button, and then click Control Panel. Click the Network and Internet Connections icon, and then click on the Network Connections tab in the appearing window.
  • Page 129 The following TCP/IP Properties window will display and the IP Address tab is open on this window by default. Figure B-3 Select Use the following IP address. And the following items will be available. If the switch's IP address is 192.168.0.1, specify IP address as 192.168.0.x (x is from 2 to 254), and the Subnet mask as 255.255.255.0.
  • Page 130: Appendix C: Glossary

    Appendix C: Glossary Boot Protocol (BOOTP) BOOTP is used to provide bootup information for network devices, including IP address information, the address of the TFTP server that contains the devices system files, and the name of the boot file. Class of Service (CoS) CoS is supported by prioritizing packets based on the required level of service, and then placing them in the appropriate output queue.
  • Page 131 Internet Group Management Protocol (IGMP) A protocol through which hosts can register with their local router for multicast services. If there is more than one multicast switch/router on a given subnetwork, one of the devices is made the “querier” and assumes responsibility for keeping track of group membership. IGMP Snooping Listening to IGMP Query and IGMP Report packets transferred between IP Multicast routers and IP Multicast host groups to identify IP Multicast group members.
  • Page 132 Remote Authentication Dial-in User Service (RADIUS) RADIUS is a logon authentication protocol that uses software running on a central server to control access to RADIUS-compliant devices on the network. Remote Monitoring (RMON) RMON provides comprehensive network monitoring capabilities. It eliminates the polling required in standard SNMP, and can set alarms on a variety of traffic conditions, including specific error types.