1. INTRODUCTION
The TOWER 10 AM PIR and TOWER 12 AM Dual Technology are
professional vandal resistance Anti-Masking detectors designed for
large commercial and industrial applications providing wide coverage
with superior resistance to harsh environment, employing several
revolutionary patented technologies
50131-1 Grade 3.
Features:
 V-slot recessed small window technology (patent pending) for
extreme mechanical robustness and protection from false alarms
(patent pending).
"Obsidian Black Mirrors"™ and "Elliptic / Parabolic Mirror"
technology providing over 15,000 LUX resistance to white light and
multiple-solid curtain pattern with 50% better sensitivity than
comparable mirror optics (several patents pending).
 Adaptive Active Infra-Red Anti-Masking technology providing the
most advanced reliable protection against intentional masking
attempts (patent pending).
 Optional interchangeable Long-Range Curtain mirror providing 35m
x 2.5m (115ft x 8.2ft) coverage for TOWER-10 and 25 x 2m (82 x
6.5ft) coverage for TOWER-12.
 Installer friendly features:
Built-in selectable E.O.L. resistors for alarm, trouble and tamper outputs.
Plug-in terminals attached to base for easy pre-wiring.
Unique sliding closing mechanism with captive screw.
Extended mounting height 1.5 - 4m (5 - 13 ft.).
Low supply voltage indication.
Remote controlled walk-test input.
Optional mounting brackets.
Selectable range adapted to the protected area size by use of a
Range Selector (TOWER 12 AM).
 Microprocessor controlled, digital TMR signal processing with dual-
slope digital temperature compensation.
 Front and Back tamper.
 True "Creep zone" down looking optics.
 Pet immunity (18Kg/40lb) using a special "pet mask".
 Built-in auto diagnostic for both PIR and microwave detectors.

2. SPECIFICATIONS

OPTICAL
Wide Angle
TOWER 10 & 12
coverage
25mx30m / 90º
Far Field Of View (FOV)
11 curtains
Medium FOV
6 curtains
Event counter settings
Mounting:
Method: Surface, corner or at 45º to wall.
Height: 1.5 - 4m (5-13 ft.) without bracket.
Vertical adjustment: Angled base surface provides three tilt
adjustments according to mounting height and coverage range.
ELECTRICAL
Sensors type:
PIR: dual element low noise pyroelectric sensor.
MW: X-Band Doppler module.
For UK - 10.687 GHz,
For EU / USA – 10.525 GHz..
For German/Czech 9.35 GHz
D-300909 TOWER 10 AM, TOWER 12 AM Installation Instructions
.
Both detectors comply with EN
Mirror Types (see Fig. 2)
Long Range Curtain
TOWER 10
TOWER 12
35m / 5º
25m / 5º
1 curtain
1 curtain
1 or 2
LR
EN: Yellow, red & green LEDs
SP: LEDs amarillo, rojo y verde
PT: LEDs amarelo, vermelho e verde
Figure 1 - TOWER 10 AM / TOWER 12 AM
Supply voltage: 8 – 16 VDC.
Low voltage detection: If input voltage is below 7.5 VDC.
Supply current:
Standby @ 12 VDC: 12mA (TOWER 10 AM). 15 mA (TOWER 12).
Maximum: 14mA (TOWER 10 AM). 18 mA (TOWER 12).
Alarm period: 2 to 3 sec.
Masking detection delay: 30 sec.
Remote LED enable input (TST): High impedance input. Affects
LEDs operation only if internal LEDs selector is set to OFF.
Outputs:
Alarm output: Solid State Relay. NC, 100 mA / 30 V, 35 ohm
maximum internal resistance. "Open" for 2 – 3 sec. in case of
alarm, masking event or complete power failure.
Trouble output: Solid State Relay. NC, 100 mA / 30 VDC, 35 ohm
maximum internal resistance. "Open" in case of auto-diagnostic
failure, Anti-Mask event, low voltage or complete power failure.
Tamper output: NC switch, 50mA / 30 VDC. "Open" by opening
detector's cover or removing it from mounting surface.
Built-in End Of Line resistors circuit: Selectable serial resistors for
each of the three outputs.
Resistors values: (tamper & alarm) ∞, 1kΩ, 2.2kΩ, 4.7kΩ, 10kΩ,
(trouble) ∞, 1kΩ, 2.2kΩ, 3Ω, 39kΩ (see figure 5).
LED indications:
Event / status
TOWER 12
Low voltage
Warm-up
Yellow + Red + Green
(60sec.)
flashing alternately
Self-test failure
Yellow + Red flashing simultaneously
AM detection
ALARM
PIR detection
Green flashing
MW detection
Green ON
Warm-up time: 60 sec.
ENVIRONMENTAL
Operating Temperature: –20°C to 55°C (-4°F to 131°F).
Storage Temperature: –20°C to 60°C (–4°F to 140°F)
RFI Protection: Greater than 20 V/m (up to 2 GHz).
Housing: IP41 and IK04 .
Dimensions: 160x77x47mm (6-5/16 x 3 x 1-13/16 in.)
Optional ACCESSORIES:
BR-1: Surface mounted swivel bracket, adjustable 30° down and 45°
left/45° right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
CURTAIN-10/12: Interchangeable long range 35m/5° curtain mirror
PET-10/12: Pet mask provides 18Kg/40Lb pet immune for wide angle
mirror only.
Standards:
Designed to comply with EN50131-1 Grade 3 / Class II,
EN50131-2-2, EN50131-2-4, EN300440, EN301489, EN60950.
Belgium standard TO14.
Sweden standard: SSF 1014.
3. INSTALLATION
3.1 General Guidance
3.2 Installation Procedure
3.3 Jumpers setting
Indication
TOWER 10 AM
Red flashing
Yellow + Red
flashing alternately
Yellow ON
Red ON
---
---
(See figure 3)
(See figure 4 & 5)
(See figure 5)
1

Advertisement

loading

Summary of Contents for Visonic TOWER 10 AM

  • Page 1: Specifications

    Supply voltage: 8 – 16 VDC. 1. INTRODUCTION Low voltage detection: If input voltage is below 7.5 VDC. The TOWER 10 AM PIR and TOWER 12 AM Dual Technology are Supply current: professional vandal resistance Anti-Masking detectors designed for Standby @ 12 VDC: 12mA (TOWER 10 AM). 15 mA (TOWER 12).
  • Page 2: Especificaciones

    Entrada de Test de paseo controlada remotamente. 1. INTRODUCCIÓN Soportes de montaje opcionales. TOWER 10 AM PIR y TOWER 12 AM Doble Tecnología, son Área de protección ajustable mediante Selector de Rango (TOWER detectores profesionales anti-vandálicos y Anti-Masking, diseñados 12 AM).
  • Page 3: Instalación

    Detección de Baja tensión: Si la tensión es inferior a 7.5 VDC. paso 4a). Corriente de Alimentación: Standby @ 12 VDC: 12mA (TOWER 10 AM). 15 mA (TOWER 12). 3.6 Test Máximo: 14mA (TOWER 10 AM). 18 mA (TOWER 12).
  • Page 4 PORTUGUESE 1. INTRODUÇÃO ELÉCTRICA Tipo de Sensores: O TOWER 10 AM PIR e o TOWER 12 AM são detectores de dupla PIR: sensor piroelectrico duplo elemento de baixo ruído. tecnologia Anti-Mascara profissionais resistentes ao vandalismo, MW: Módulo “X-Band Doppler” desenhados para aplicações comerciais e industriais com grande UK - 10.687 GHz, EU / USA –...
  • Page 5 é conforme as indicações do fornecedor. Este produto não é para deitar for a como o lixo diário. Directiva 2002/96/EC Lixo de Equipamentos Eléctricos e Electrónicos. D-300909 TOWER 10 AM, TOWER 12 AM Installation Instructions...
  • Page 6 SP: Agujeros para tornillos de tamper trasero sin conos (para mayor robustez). PT: Orifício para parafuso do tamper traseiro – sem cone (para adicionar força) Fig. 4 - Mounting / Montaje/ Montagem D-300909 TOWER 10 AM, TOWER 12 AM Installation Instructions...
  • Page 7 Figure 6 - TOWER-10 AM Long Range Mirror and Pet Mask Replacement / Espejo Largo Alcance TOWER 10 AM y sustitución de filtro antimascota / Espelho Longo Alcance TOWER 10 AM e recolocar mascara animal. TOWER 10 - 1AM, TOWER 12 - 1AM EN: ALARM CONTRO L PANEL.
  • Page 8 VISONIC GmbH (D-A-CH): KIRCHFELDSTR. 118, D-40215 DÜSSELDORF, TEL.: +49 (0)211 600696-0, FAX: +49 (0)211 600696-19 VISONIC IBERICA: ISLA DE PALMA, 32 NAVE 7, POLÍGONO INDUSTRIAL NORTE, 28700 SAN SEBASTIÁN DE LOS REYES, (MADRID), ESPAÑA. TEL (34) 91659-3120, FAX (34) 91663-8468. www.visonic-iberica.es INTERNET: www.visonic.com...

This manual is also suitable for:

Tower 12 am