Download Print this page
Vinotemp VT-12TEDS Service Manual
Hide thumbs Also See for VT-12TEDS:

Advertisement

\

Tools for repair

1
Screw driver
2
Multimeter
3
Plier
4
Electric Iron
SERVICE MANUAL FOR
VT-12TEDS
VT-16TEDSW, VT-28TEDS-T

Advertisement

loading

Summary of Contents for Vinotemp VT-12TEDS

  • Page 1 SERVICE MANUAL FOR VT-12TEDS VT-16TEDSW, VT-28TEDS-T Tools for repair Screw driver Multimeter Plier Electric Iron...
  • Page 2 Problems and troubleshooting The wine cellar does not work (1). Check to ensure the power plug is installed properly, if not connect or loosen, please connect it properly (2). If there is no problem with the power plug, please unplug the machine and open the back cover.
  • Page 3 Plug it in after open the back cover Test the voltage at the connector of the power cord, (please take care of the high voltage) AC100 120V If the voltage is not within AC100 120V, that means the power cord is broken, please change the power cord.
  • Page 5 AC100 120V DC12 13V If the voltage is within AC100 120V, then test the output voltage, if the voltage is not within DC12 13V, then it must be the problem of the PCB, change the PCB. Change PCB...
  • Page 6 Here is for connecting the anti-frost NTC from the cooling system Here is for connecting the heat Here is for connecting the cold Here is for connecting the temperature controller here Cut the fastener...
  • Page 7 disconnect all the connectors Take out the screws on the PCB Melt the two wires from thermoelectric module on the cooling system...
  • Page 9 DC1.9 13V Test the voltage with Multimeter, if voltage is DC1.9 13V, but the temperature LED no display, Test the input connect on the PCB for the temperature controller...
  • Page 10 If there is no DC voltage, it means the PCB is broken, change a new one. DC7.6 8.1V If there is a voltage within DC7.6 8.1V, then test the temperature controller Pull out the magnetic seal Take out the three screws...
  • Page 11 Take out the temperature controller Check whether the connectors are loosen...
  • Page 12 DC7.6 8.1V Test the voltage on the connector If the voltage is not within DC7.6 8.1V, that means the wire is broken, change it. If the voltage is within DC7.6 8.1V, that means the temperature control is broken, change it. Here is for the interior LED light wires, and temperature control wires...
  • Page 13 Change a new temperature control PCB The inside temperature is not low enough Check whether the temperature setting is the one you want Check whether the door is opened too often. Check whether the door is well closed Check whether the magnetic seal on the door frame is in good condition Check whether there is too much dust on the anti-dust net, Check whether the ventilation on the two sides are hided.
  • Page 14 Check whether the cold fan is working well If it is not working, check whether the connectors are loosen. , If the connectors are good, then change the cold fan...
  • Page 15 Check whether the hear fan(s) are working well If it is not working, check whether the connectors are loosen...
  • Page 16 If the connectors are not loosen, then change new the fan(s)
  • Page 17 If both of the cold fan and hear fan(s) are working well DC9 13V then test the output voltage, check whether it is within DC9 13V If it is not, change the temperature controller DC9 13V If it is within DC9 13V, change the cooling system...
  • Page 19 Noise during operation Check whether the unit is placed evenly. Check whether there is something in the heat fan(s), if yes, clean it. Check whether there is something in the cold fan, if yes, clean it.
  • Page 20 If there is some ice on the cold aluminum, turn off the machine for some time...
  • Page 22 No display on the temperature controller Check there is power Check whether there is input voltage Display error on temperature LED display Check whether the NTC connectors on the temperature controller is loosen Check whether the wires from the NTC is broken. Buttons on temperature controller does not function Change the controller (see instruction in previous pages)
  • Page 23 Interior light does not work Check whether for the interior light on the temperature controller is in good condition. Check the wires for the light is well connected.
  • Page 24 If the wires and connectors are in good condition, change the light PCB.