IMPORTANT: READ ALL OF THESE INSTRUCTIONS BEFORE INSTALLING THE SENSOR.
Read and follow the manufacturer instructions carefully. All wiring must conform to local and national
electrical codes. Improper wiring or installation may damage the sensor.
Recognize safety information. This is the safety alert symbol
equipment or in the instruction manual, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety alert
symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death.
WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify
unsafe practices which may result in minor personal injury or property damage.
The Remote Sensor measures indoor air temperature and will send this information to the thermostat. The
sensor measures temperature with a range of -20° to 120° F. The sensor also has an OVERRIDE button which
will place the thermostat into the override mode for two hours. For information on override operation please
consult the Owner's Manual of your thermostat.

Sensor Location

CORRECT LOCATIONS
frequently used room, preferably on an inside partitioning wall or on a section of wall without pipes or ductwork. Mount
the sensor where temperature operating limits are within -20 to 120 F and the humidity operating range is within 0 to 95%
relative humidity, non-condensing.
INCORRECT LOCATIONS
a door leading to the outside. Do not mount the sensor in a location where it would be exposed to direct light and heat
from a lamp, the sun, a fireplace, or any other temperature-radiating object which may cause a false reading. Finally, do
not mount the sensor close to or in direct airflow from supply registers or return air grilles and in areas with poor air
circulation (such as behind a door or in an alcove).

Sensor Installation

INDOOR INSTALLATION
the sensor:
1. Place the Remote Sensor wall plate on the wall. Mark the
mounting screw holes on the wall through the holes in the
wall plate.
2. Drill two 3/16-in. mounting holes in the wall at the location
marked in Step 1.
3. Mount the Remote Sensor wall plate to the wall with the
screws provided.
Sensor Assembly
Align and press the Remote Sensor circuit
board onto the wall plate as shown. Install the
button onto the circuit board.
Note: The OVERRIDE button can be disabled
by putting non-conductive tape over the
switch pad before installing the OVERRIDE
button onto the circuit board.
©Venstar Inc. 8/11
REMOTE SENSOR
with OVERRIDE BUTTON

SAFETY CONSIDERATIONS

The Remote Sensor should be mounted approximately five feet from the floor, close to or in a
The Remote Sensor should NOT be mounted close to a window, on an outside wall, or next to
Perform the following procedures to install
White
. When the safety alert symbol is present on

GENERAL

Screw hole
Through hole
for wires
Screw hole
Black
MODEL
ACC-TSENWB
Remote Sensor
Wall Plate
OVERRIDE
button
White
White
Black
P/N 88-941
Black
Rev. 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACC-TSENWB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Venstar ACC-TSENWB

  • Page 1: Sensor Installation

    Install the button onto the circuit board. Note: The OVERRIDE button can be disabled Black Black Black by putting non-conductive tape over the switch pad before installing the OVERRIDE button onto the circuit board. ©Venstar Inc. 8/11 P/N 88-941 Rev. 1...
  • Page 2 NOTE: All sensor wiring -6.7 36519 must be in compliance -1.1 28558 with all applicable local and national codes. 22537 17926 15.6 14356 21.1 11578 26.7 9398 32.2 7672 37.8 6301 43.3 5203 ©Venstar Inc. 8/11 P/N 88-941 Rev. 1 48.9 4317...

Table of Contents