WIRELESS KITS (DT01*, DS01*, DD01*)
DS01*
for additional assistance and explanation prior to ordering materials or cutting openings.
USE ONLY ONE DD01* PASSIVE INFRARED MOTION SENSOR (PIR) DOOR SWITCH
COMBINATION DEVICE AND/OR ONE DS01* TO ONE DIGISMART PTAC UNIT.
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to know the product better than the customer.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual.
Pay special attention to all safety warnings. Often during installation or repair
it is possible to place yourself in a position which is more hazardous than when the unit is in operation.
Remember, it is your responsibility to install the product safely and to know it well enough
The precautions listed in this Installation Manual are intended as supplemental to existing practices.
However, if there is a direct conflict between existing practices and the content of this manual,
November 2007
IO-644D
I
NSTALLATION
IO-644C~IO-644C~092007~4
The following installation instructions are for a typical installation.
Please contact your PTAC salesperson
This includes all safety precautions and related items.
to be able to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of thinking before acting.
Most dealers have a list of specific good safety practices...follow them.
the precautions listed here take precedence.
is a trademark of Maytag Corporation and is used
®
under license to Goodman Company, L.P. All rights reserved.
PTAC
I
NSTRUCTIONS
AIR CONDITIONING SENSOR
DD01*
DT01*

Advertisement

loading

Summary of Contents for Amana DT01 Series

  • Page 1 PTAC WIRELESS KITS (DT01*, DS01*, DD01*) NSTALLATION NSTRUCTIONS AIR CONDITIONING SENSOR DD01* IO-644C~IO-644C~092007~4 DT01* DS01* The following installation instructions are for a typical installation. Please contact your PTAC salesperson for additional assistance and explanation prior to ordering materials or cutting openings. USE ONLY ONE DD01* PASSIVE INFRARED MOTION SENSOR (PIR) DOOR SWITCH COMBINATION DEVICE AND/OR ONE DS01* TO ONE DIGISMART PTAC UNIT.
  • Page 2 5. Remove antenna cable and route cable through opening in bottom of antenna housing. 6. Mount antenna housing with two screws as shown in FRONT MOUNTING figure. (NOTE: The Amana ® brand logo should be in the HOLE lower right hand corner).
  • Page 3 .2. Remove thermostat from mounting plate by pulling apart. 2. Mount the back plate on the door trim directly above the door using the enclosed screws. Mount the DD01* as 3. Place thermostat mounting plate against the wall at de- low as possible on the door frame to be as close to the sired location and mark placement of mounting holes.
  • Page 4 Door Magnet Installation Mount the door magnet holder on the front of the door where it will be as close as possible to the bottom of the motion sensor but no more then 1/8" from the bottom center of the motion sensor (DD01*) when the door is closed. Select the correct slot in the magnet holder (there are three slots) to obtain 1/2"...
  • Page 5 Select one of the three slots that places the magnet ½” from the sensor mounting plate on the door frame. See expamples below. The door frame and door usually will not align. Place holder on the door and select the slot that places the magnet as close as possible to the ½”...
  • Page 6 Binding of RF Devices 2. Press and then immediately release the white tactile button on the back of the DS01* thermostat. should now be displayed on the PTAC LED display. If does not show on the display in 1-2 seconds, then press and release the white button a second time.
  • Page 7: Configuration Settings

    Configuration Settings The PTAC control will automatically self-configure to work with the wall thermostat (DS01* Kit) if installed. The PTAC control will automatically self-configure to activate pre-configured energy management routine when the DD01* is installed and bound to the PTAC. Additionally, the setback times and setback temperatures can be changed using the configuration settings.
  • Page 8 Setback Temps - DD01* The DD01* and the DigiSmart control can be programmed for 3 different times to activate temperature setbacks. The current factory default temperature setbacks in v2.5 * software release are: 2º from set point in 30 minutes, 3º in one (1) hour, and 6º...
  • Page 9 7. Press HEAT key to scroll to second unoccupied setback time. Press either the up or down arrow the desired second unoccupied setback time. Example: Operating set point would be 76 instead of 72, one hour (1.0 hour) after guest leaves room. 8.
  • Page 10 Typical Room Layouts PTAC PTAC MOTION MOTION SENSOR SENSOR OUTSIDE OUTSIDE C A U TIO N NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC This equipment is authorized for use under the Rules.
  • Page 11 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 12 Due to policy of continued product improvement, the right is reserved to change specifications and design without notice. ® is a trademark of Maytag Corporation and is used under license to Goodman Company, L.P. All rights reserved. Goodman Company, L.P. • 5151 San Felipe, Suite 500 Houston, TX 77056 www.amana-ptac.com © 2005 - 2007 Goodman Company, L.P.

This manual is also suitable for: