Installing A Cp-10 Remote Control Panel; General Specifications - AMX CP-10 Instruction Manual

Autopatch control panel
Hide thumbs Also See for CP-10:
Table of Contents

Advertisement

Installing a CP-10 Remote Control Panel

Installing a CP-10 Remote Control Panel
This chapter covers rack installation for the CP-10 Remote Panel (FG1090-216), as well as instructions
for linking the panel to an enclosure. When the installation is complete, execute a test switch to make
sure the system is working properly (see page 15).

General Specifications

Parameter
Cable for XNNet
Communications
Power
Operational Temperature
Humidity
Dimensions
Weight
Rear View
FIG. 4
Rear view of CP-10 Remote Panel
12
Two-conductor, 20 AWG, 7/28 strand cable with a drain wire or shield, such
as Alpha 2412C (customer supplied)
Maximum length of cable: 1000 ft. (305 m) total, including linked panels
+7 VDC to +12 VDC @ 500 mA
32° F to 110° F (0° C to 43° C)
0 to 90% non-condensing
1.0 in. (2.54 cm) depth
18.9 in. (48.0 cm) width with mounting ears
5.2 in. (13.21 cm) height, 3 RU
Approximately 2 lb (0.91 kg) per panel
Power connector
Value
Comm Link connector
CP-10 Instruction Manual