American Dynamics EDVR Quick Setup Manual page 6

Edvr unit
Hide thumbs Also See for EDVR:
Table of Contents

Advertisement

H. Connecting ADTT16E to EDVR
1 Connect the hardware. Refer to the following diagram:
EDVR
2 Configure the Touch Tracker (Config Devices). Set Configure Devices to MUX 16 Duplex or
Triplex.
Note
Do not use MUX 16 posem.
3 To configure the COM port, press the MENU button. Select Advanced Settings >
Communication > RS232 Settings using the arrow buttons or jog dial and pressing the ENTER
button. Set Baud Rate to 9600 using the shuttle ring and then press the ENTER button. Keep
pressing the MENU button to return to the Main Menu.
4 To configure dome settings, press the MENU button. Select > Advanced Settings > Dome
Settings using the arrow buttons or jog dial and pressing the ENTER button.. Highlight the
camera, set the ID (integer 1-254) using the shuttle ring. Move to the protocol column and
select the protocol using the shuttle ring. Press the ENTER button (AD422 only). Keep
pressing the MENU button to return to the Main Menu.
BNC Video
RS232
9600 Baud
EIM
RS232 over
Cat 5 Cable
8200-0841-00 A0
EDVR Quick Setup Guide
Sensornet
DOME
Power
Set Configure Deivces to
MUX 16 Duplex/Triplex
Note: Do not use MUX 16 posem
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents