Download Print this page
Aiphone GH-VAX Instructions
Aiphone GH-VAX Instructions

Aiphone GH-VAX Instructions

Cctv interface module for gh multi-unit video entry system

Advertisement

Quick Links

CCTV Interface Module for GH Multi-Unit Video Entry System
The GH-VAX is a video module that provides a connection for an external CCTV camera for viewing a wide area
surrounding the GH entrance panel. When a visitor calls from the entrance station, the view from the separate CCTV
camera will be seen on the tenant's monitor station. The GH-VAX module will be installed in the entrance panel, but
will not be seen.
ENTRANCE PANEL CONFIGURATION:
1. The GH-VAX module takes the place of the standard GH-VA module, and must be located in the
entrance panel.
2. A blank plate (GF-BP) is required to cover the GH-VAX, so it will be out of sight from the outside
of the panel.
3. The remote CCTV camera connects to the back of the GH-VAX module as shown below. The
camera location is intended to provide a wider view of the lobby or entry area, other than a direct
frontal view of the visitor.
4. Build the remainder of the GH entrance panel in the same manner as any other GH station, with
the GH-DA Audio Module connected directly with the GH-VAX, then all other modules connected
as designated in the GH Installation & Operation Manual.
5. Programming and operation of the GH entrance panel is the same as the standard GH panel, The
only difference is that the video signal is from a remote camera instead of resident in the panel.
WIRING DIAGRAM:
- INSTRUCTIONS -
GH-VAX
(rear view)
A1 A2
CN3
To GH-DA
(see GH Installation Manual)
Gray wire (video in, +)
Gray w/black stripe (video in, ground)
GH-VAX:
This unit is used in place of a standard
GH-VA, so there is no camera built into
the entrance panel. The only video is
from the external CCTV camera.
Video wire #871802
Coax
CCTV Camera
To GH-VBC
(see GH Installation Manual)

Advertisement

loading

Summary of Contents for Aiphone GH-VAX

  • Page 1 1. The GH-VAX module takes the place of the standard GH-VA module, and must be located in the entrance panel. 2. A blank plate (GF-BP) is required to cover the GH-VAX, so it will be out of sight from the outside of the panel.
  • Page 2 OPTIONAL CONFIGURATION (Stand-alone CCTV Adaptor): 1. GH-VAX can be used as a stand-alone CCTV adaptor if system capacity allows it. This station counts as and is programmed as an entrance panel. 2. Stand-alone camera panel should be comprised of (1) GH-VAX, (1) GF-BP, (1) GH-DA, (1) GH-DP, (1) GF-2F.