Download Print this page

Aiphone LEM-1DL Instruction Manual page 2

Single master station with door release

Advertisement

WIRING DIAGRAM: Dual Master LEM-1DL System with DAK-2S Dual Master Adaptor
LE-D
1
E
Leave
-
E/- jumper
attached
If using a non-Aiphone door strike,
!
use a separate power source for the
door release mechanism.
Aiphone EL-12S
OPERATION NOTES:
1. Only one master can be used at a time.
2. If both masters are activated, a feedback (squeal) will be heard through the system when either TALK button is pressed.
3. If feedback occurs, press the OFF button on one of the LEM-1DL masters.
INSTALLATION GUIDELINES:
1. Use 2 conductor shielded wire from the door station to the first master, then to the second master.
2. Install the units at the desired locations.
3. Separate PT-1210N power supplies are required for each master station. NOTE: Connect power leads to master BEFORE plugging in power supply
4. Install the bare wire leg of the component module directly onto the "1" terminal of the LEM-1DL's.
5. Attach the wire coming form the "1" terminal of the LE-D to the colored wire end of the component modules at both masters. (The component
modules will easily fit within the space available.)
6. Connect the "E" terminals between the door station and master stations.
7. If door release is included, use a separate 2-conductor wire from the "EL" terminals of the masters through an AC transformer and to the door strike.
8. The EL-12S is designed for a standard wood framed door, and for light and medium usage. If a different type of door is used, install a strike
appropriate for the door.
9. The door release button on the master station is a "Normally Open" contact closure. Contact rating is 30V AC/DC @ 1 Amp.
4 LEM-1DL Master Stations with 1 Door
LE-D
1
Component
E
-
PT-1210N
Door Strike
Power Source
for door strike
LEM-1DL Supplement
Pg. 2
Component
Module
LEM-1DL
1
Component
Module
E
PT-1210N
+
-
EL
EL
Please read and understand all
LEM-1DL
instructions before installation.
1
E
PT-1210N
+
-
EL
EL
IMPORTANT!!!
Each master REQUIRES an individual power supply.
Note: In a multi-master system, all masters only talk to the
door station, and only one master can be on at a time
LEM-1DL
1
Module
E
PT-1210N
+
-
EL
EL
LEM-1DL
1
Component
Module
E
+
-
EL
EL
LEM-1DL
Component
Module
1
E
PT-1210N
+
-
EL
EL
LEM-1DL
1
Component
Module
E
PT-1210N
+
-
EL
EL