ADTRAN Total Access 1500 Chassis 1180001L1 Installation And Maintenance Practice

ADTRAN Total Access 1500 Chassis 1180001L1 Installation And Maintenance Practice

Advertisement

SCU
LIU
1180008L2
1180109L1
A
R
T
C
C
D
I
R
M
A
I
P
RED
F
N
T
G
YEL
RCV
REM
TEST
MJR
HST
MASTER
STATUS
MNR
MLT
BSY
RMT
ACO
MONITOR
PSU-A
PSU-B
SCU
PSU-A
CONTENTS
1. General .................................................................... 1
2. Installation............................................................... 3
3. Maintenance .......................................................... 12
4. Warranty and Customer Service ........................... 14
5. Specifications ........................................................ 14
FIGURES
Figure 1. Total Access 1500 Chassis .......................... 1
Figure 6. Ring Generator Connector ........................... 7
Figure 9. Alarm Contacts .......................................... 10
Figure 10. RS-485 Wiring......................................... 13
TABLES
Table 1. Compliance Codes ........................................ 2

1. GENERAL

This practice is an installation and maintenance guide
for the ADTRAN Total Access
(P/N 1180001L1#S), illustrated in

Revision History

This is the fourth issue of this practice. This release adds
a note concerning wiring of the Composite clock input
when using the 1180009L1 Dual LIU and the
1180109L1 Quad LIUs. (See
page 7.)
61180001L1#S-5D
®
Total Access 1500 Chassis
Installation and Maintenance Practice
LIU
POTS RT
POTS RT
POTS RT
POTS RT
POTS RT
POTS RT
1180109L1
1180408L1
1180408L1
1180408L1
1180408L1
1180408L1
A
R
BUSY
BUSY
BUSY
BUSY
BUSY
C
D
1
1
1
1
1
P
RED
2
2
2
2
2
YEL
RCV
3
3
3
3
3
REM
TEST
4
4
4
4
4
MASTER
STATUS
TX
TX
RX
RX
MONITOR
LIU-B
1
2
3
4
5

Figure 1. Total Access 1500 Chassis

1500 Chassis
®
Figure
1.
Data Connections
on
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.
POTS RT
POTS RT
POTS RT
POTS RT
POTS RT
POTS RT
POTS RT
1180408L1
1180408L1
1180408L1
1180408L1
1180408L1
1180408L1
1180408L1
1180408L1
BUSY
BUSY
BUSY
BUSY
BUSY
BUSY
BUSY
BUSY
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
6
7
8
9
10
11
12
Features
The basic features of the Total Access 1500 Total
Access 1500 Chassis include the following:
• Rackmount design
• Scalable network connectivity
• 1-5 T1 capacity (4 T1s and a Protect T1 for TR-08
applications using a Quad LIU)
• Three common units:
- Power Supply/Ring Generator (PSU/RGU)
- System Controller Unit (SCU)
- Line Interface Unit (LIU)
• T1 Network Interface
• 24 slots for combination of voice and data services
• Variety of access module units
• Network management capabilities (TL1, SNMP)
• Multiple configuration arrangements
• TR-08 compatible (Modes 1, 2, and 3)
• Supports Mechanized Loop Testing (MLT)
• NRTL Safety Listed and FCC compliant
• Meets NEBS Level 3 requirements
General Description
The Total Access 1500 Chassis is designed to meet a
variety of operating configurations and services, such as
POTS and Special Services. The Total Access 1500 is
intended for use in central office, remote terminal, and
customer premise applications. The Total Access 1500
System is comprised of the chassis, common cards, and
access modules.

Physical Description

The Total Access 1500 chassis is 23 inches wide by
3.50 inches high by 10.75 inches deep and is made of
heavy gauge metal. The unit mounts in a standard 23-
inch wide rack.
Section 61180001L1#S-5D
Issue 4, February 2009
CLEI Code: VAM5K00F_ _
POTS RT
POTS RT
POTS RT
POTS RT
POTS RT
POTS RT
POTS RT
1180408L1
1180408L1
1180408L1
1180408L1
1180408L1
1180408L1
1180408L1
BUSY
BUSY
BUSY
BUSY
BUSY
BUSY
BUSY
1
1
1
1
1
1
1
2
2
2
2
2
2
2
3
3
3
3
3
3
3
4
4
4
4
4
4
4
13
14
15
16
17
18
19
20
1500
POTS RT
POTS RT
POTS RT
POTS RT
1180408L1
1180408L1
1180408L1
1180408L1
BUSY
BUSY
BUSY
BUSY
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
21
22
23
24
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Total Access 1500 Chassis 1180001L1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADTRAN Total Access 1500 Chassis 1180001L1

  • Page 1: Table Of Contents

    The Total Access 1500 Chassis is designed to meet a This practice is an installation and maintenance guide variety of operating configurations and services, such as for the ADTRAN Total Access 1500 Chassis ® POTS and Special Services. The Total Access 1500 is...
  • Page 2: Table 1. Compliance Codes

    Most access modules occupy one slot in Changes or modifications not expressly approved by the Total Access chassis. ADTRAN could void the user’s authority to operate this The access modules supported by Total Access 1500 are equipment. listed in the Total Access 1500 System Manual (P/N 61180001L1#S-1).
  • Page 3: Installation

    Attaching the mounting brackets to the shipping or handling. If damage has occurred, file a shelf requires four screws on each side, and are supplied claim with the carrier, then contact ADTRAN. Refer to with the unit. Warranty and Customer Service section.
  • Page 4: Figure 3. Mid-Mount Bracket Orientation

    • Mid-mount: To mid-mount a shelf in the rack, use a Once the orientation of the chassis has been determined, #2 phillips-head screwdriver and attach the mount- use four screws suitable to the CO rack and an appro- ing brackets (see Figure 3) with the flanges priate screwdriver to secure the Total Access 1500...
  • Page 5 Frame Ground Connection The number of shelves that can be placed in a 7-foot The frame ground terminal, located on the upper right central office rack depends on the type of service corner of the backplane (see Figure 4 Figure deployed and the number of access modules in the shelf.
  • Page 6: Figure 5. Total Access 1500 Backplane And Pinouts

    Figure 5. Total Access 1500 Backplane and Pinouts Issue 4, February 2009 61180001L1#S-5D...
  • Page 7: Figure 6. Ring Generator Connector

    Apply Power and Check Voltage Before proceeding further, ensure that power has been correctly applied to the shelf. The proper voltage to 3 TB2 Total Access 1500 is –48 VDC, with an operating range of –42 VDC to –56 VDC. WARNING Installing fuses in the fuse alarm panel at this stage will provide power to the shelf.
  • Page 8: Figure 7. Redundant Composite Clock Wiring

    4. Wire wrap the “–” wire from the clock source to 2. Using wire strippers, strip approximately 1 to the pin marked “–” on connector 1-1/2 inches from both ends of the wire run. CLKINP 5. Wire wrap the drain or shield wire from the clock 3.
  • Page 9: Figure 8. Daisy-Chained Composite Clock Wiring

    – – CO TIMING – – – – TERMP C L K I N S C L K O U T S C L K I N P C L K O U T P R T1 R1 R T1 R1 R T1 R1 R T1 R1 R T1 R1...
  • Page 10: Figure 9. Alarm Contacts

    Connect MLT The Total Access 1500 provides standard bank alarm Metallic Loop test access is gained by wiring into the outputs. Each of the alarms listed below consists of a connector , on the right side of the backplane. three-pin wire-wrap header that connects to the SCU for alarm management.
  • Page 11 NOTE NOTE Each three-pin alarm header is wired the same Omit step 5 if the alarmed piece of equipment way for the specified alarm. has its own source of –48 VDC and does not need the –48 VDC feed from the Total Access 1500 shelf.
  • Page 12: Maintenance

    Repair services may be obtained 2. Connect the other end of the data cable to the by returning the defective unit to ADTRAN. For more designated port of the X.25 switch. information, refer to Warranty and Customer Service section for further information.
  • Page 13: Figure 10. Rs-485 Wiring

    – RS485 R T1 R1 R T1 R1 R T1 R1 R T1 R1 R T1 R1 – – – – NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC -48 TERM TERM P + –...
  • Page 14: Warranty And Customer Service

    4. WARRANTY AND CUSTOMER SERVICE 5. SPECIFICATIONS ADTRAN will replace or repair this product within the Specifications for the Total Access 1500 Total Access warranty period if it does not meet its published specifi- 1500 Chassis are detailed in Table cations or fails while in service.

This manual is also suitable for:

Total access 1500

Table of Contents