Gemini GEM-P816 Installation Instructions Manual page 38

Control panel/communicator
Hide thumbs Also See for Gemini GEM-P816:
Table of Contents

Advertisement

!
Page 38
Print Module Support
The bus mounted GEM-PRINT will print all system activity. If the GEM-PRINT fails, it will cause an E27- 00 Printer Fail system trouble.
Priority Area Arming
Prevents area arming if the alternate Priority Area has not yet been armed.
Priority Zone (Required for all zones in UL installations.)
A zone that will prevent arming if faulted. If an attempt is made to arm, the sounder will come on and "
will be displayed for 4 seconds. The keypad may be reset by simply pressing the
corrected before the panel can be armed. Any zone may be selected as a Priority Zone. A zone in trouble that is neither a Priority Zone
nor an Auto-Bypass Zone will cause an alarm on arming.
Priority Zone with Bypass
A Priority Zone that will permit arming if the priority condition is bypassed. If the system is so programmed, the zone will auto-bypass
and (optional) the condition will be reported to a central station.
As above, if an attempt is made to arm, the sounder will come on and "
keypad, press the
C
button; the display will read "
U
number, then press the
button. Any zone not selected as a Priority Zone may be programmed as a Priority Zone with Bypass.
Pulse Burglary Output See Alarm Outputs
Receiver Format
The communicator can be programmed to transmit to any standard central-station receiver format. A receiver format must be entered
for each telephone number used, but a different format may be assigned to each. Refer to Backup Report on Telco 2 and Report Telco
3 to determine whether or not Telephones 2 and/or 3 will be programmed. Call the central station for each telephone number used to
confirm the type of receiver in use. Select the receiver format entry for each telephone number from the following table.
ENTRY
blank (•)
2
3
4
5
B
C
E
*These formats do not use programmable codes, but Event ID Codes to identify the type of zone and alarm as follows:
1 – Fire
2 – Panic
3 – Burglary
4 – Holdup
7 – Gas Alarm
8 – Heat Alarm
A – Auxiliary Alarm (keypad displays "0")
B – 24-Hour Auxiliary Alarm
Remote Panic See Panic Zone
Report Digital Dialer Exit Error/Recent Closing
A Recent Closing transmission is sent if an alarm occurs within two (2) minutes after the expiration of the Exit Time. If the user number is
available, it is included in the Recent Closing transmission. Note: Recent Closing transmissions are not sent for fire alarms.
Report Telco 1; Report Telco 3 (Double or Split Reporting)
Alarms, alarm restores, troubles and trouble restores may be selected individually for each zone. Violation of a zone selected to report
will communicate the code(s) selected for that zone to the central station.
Normally, Report Telco 1 is used to report to the central station. Report Telco 3 is used when certain zones will report to a different
receiver (split reporting); Report Telco 1 and Report Telco 3 are both used on the same zone to report to two receivers successively
(Double Reporting). (Double Reporting requires a successful report to Telco 1 before reporting to Telco 3.) Also see Backup Report on
Telco 2.
X
GEM-P816 Installation Instructions
ZONE FAULTS
RECEIVER FORMAT
Ademco, Silent Knight Slow
Radionics Fast
Silent Knight Fast
Radionics, DCI, Franklin Slow
Universal Hi-Speed
SIA*
Ademco Point ID*
Pager
(SIA CP-01 Requirement: 4.2.2.6)
C
button. The fault on a Priority Zone must be
ZONES NOT NORMAL / CAN'T ARM
". To arm the panel, press the
DATA
DUTY CYCLE
INTERDIGIT
FREQ.
(ON/OFF)
TIME
(Hz)
1900
60/40mS
600mS
1850
13/12
400
1900
40/30
560
1800
60/40
600
1850
30/20
350
Modem formats
L
WI994C 3/04
ZONES NOT NORMAL / CAN'T ARM
" will be displayed. To reset the
B
button, then enter the zone
NAPCO Security Systems
"