Central Spout - Miele CVA 5060 Operating And Installation Manual

Built-in coffee machines
Table of Contents

Advertisement

Cleaning and care

Central spout

^ Pull the central spout down as far as
it will go (a), and pull the cover to
the spout forwards to remove it (b).
^ Turn the cover around, push the
insert up and out and then clean both
parts thoroughly.
^ Slide the insert back into the cover
until it clicks into place.
^ Pull out the jets in the central spout.
54
^ Remove the two rubber stoppers
(a) and manually clean these and
the jets thoroughly. If required,
remove the air intake tube (b). Any
blockages can be dislodged by
kneading or "blowing through" the
tube.
Do not use a needle or similar
implement. This would damage the
components.
^ Replace the stoppers.
^ After cleaning, push the jets firmly
back into place on the central spout,
ensuring they are secure.
^ Replace the cover and then push the
central spout back up into position.