Current Function Specifications - Fluke 80 Series III User Manual

Fluke power supply 80 series iii users manual
Hide thumbs Also See for 80 Series III:
Table of Contents

Advertisement

Function
Range
mA
40.00 mA
\
400.0 mA
4000 mA
(45 Hz to 2 kHz)
10.00 A
mA
[
40.00 mA
400.0 mA
4000 mA
10.00 A
1.
See the first sentence in Table 11 for a complete explanation of accuracy.
2.
AC conversion for Model 83 is ac coupled and calibrated to the rms value of a sinewave input.
3.
AC conversions for Models 85 and 87 are ac coupled, true rms responding, and valid from 5% to 100% of range.
4.
See note 3 in Table 11.
W
5.
10 A continuous; 20 A for 30 seconds maximum; >10 A: unspecified.
6.
Below a reading of 200 counts, add 10 counts.
Table 14. Current Function Specifications
Resolution
0.01 mA
0.1 mA
1 mA
5
0.01 A
0.01 mA
0.1 mA
1 mA
5
0.01 A
1
Accuracy
2
3, 4
Model 83
Model 85
6
(1.2% + 2)
(1.0% + 2)
6
(1.2% + 2)
(1.0% + 2)
6
(1.2% + 2)
(1.0% + 2)
6
(1.2% + 2)
(1.0% + 2)
(0.4% + 4)
(0.2% + 4)
(0.4% + 2)
(0.2% + 2)
(0.4% + 4)
(0.2% + 4)
(0.4% + 2)
(0.2% + 2)
Specifications
3, 4
Model 87
Burden Voltage
(typical)
6
(1.0% + 2)
1.8 mV/mA
6
(1.0% + 2)
1.8 mV/mA
6
(1.0% + 2)
0.03 V/A
6
(1.0% + 2)
0.03 V/A
(0.2% + 4)
1.8 mV/mA
(0.2% + 2)
1.8 mV/mA
(0.2% + 4)
0.03 V/A
(0.2% + 2)
0.03 V/A
45

Hide quick links:

Advertisement

Table of Contents
loading