Southbend StratoSteam STRE-3D Owner's Manual page 28

Countertop steamer
Hide thumbs Also See for StratoSteam STRE-3D:
Table of Contents

Advertisement

S
ERVICE
Figure 17
Timer and Buzzer Check
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove right side panel.
3. Set timer for one minute and allow to time out. If timer does not run, then replace timer.
4. Disconnect from the timer the wire that leads to the buzzer.
5. Disconnect connector PL1 to separate the other buzzer lead wire from the wiring harness.
6. Place test leads between positions 1 and 3 on the timer (as shown above).
7. Check for continuity when the timer has run down (so the buzzer should be on). If no continuity, replace timer.
8. Disconnect other lead wire from buzzer. Place test leads in terminals of buzzer lead wires (as shown above).
9. Check that resistance is approximately 3.4 Kohms. If it is not, replace the buzzer.
10. Reconnect wires.
P
28
56
AGE
OF
1
3
Timer
Buzzer
Inside of Control Panel
S
S
E
TRATO
TEAM
LECTRIC
Continuity
Ohms
O
'
M
1189951 (10/08)
WNER