Voltage Dips, Short Interruption And Voltage Variation Immunity; Voltage Dips, Short Interruption And Voltage Variation Immunity Test - Acer VT7200D Test Report

Table of Contents

Advertisement

Voltage Dips, Short Interruption and Voltage Variation
9.
immunity

Voltage Dips, Short Interruption and Voltage Variation immunity test

9.1
Port:
Basic Standard:
Phase:
Test intervals:
Voltage Dips:
Criteria:
Voltage Dips:
Criteria:
Voltage Interruption: >95% in 250 period
Criteria:
Test Setup
To AC main
Supply
Transient-1000
Test Result
Performance of EUT complies with the given specification.
International Standards Laboratory
NVLAP Lab. Code: 200234-0; VCCI: R-341, C-354; NEMKO Aut. No: ELA 113; BSMI Lab. Code: SL2-IN-E-0013
-19-
AC mains
EN61000-4-11
3 times with 10s each
>95% in 0.5 period
B
30% in 25 period
C
C
AC power supply to EUT
Interruptions & Voltage
Dips Control
80 cm
Metal Full Soldered Ground Plane
Report Number: ISL-01A105E
To the Peripherals
EUT
Non-Metallic /
Non-Conducted Table

Advertisement

Table of Contents
loading

Table of Contents