2.3 Audio Connection

The NETWORK CAMERA enables users to send and receive a voice through the
input/output module. Use it after connecting the port to the microphone and speaker,
which have an amplifier function.

2.4 Alarm Connection

2.5 Power Connection

Power Input

2.6 Reset Button

Reset Button

2.7 Network Camera Fixation

When it comes to the general installation of the Network Camera, users can fix the Network
Camera on the stand by using a standard-sized screw hole on the top and bottom of the
main body.
●Top Fixed Installation
: This method is mainly used to install a camera on the higher places away from the
ground such as a ceiling or a dome camera stand.
●Bottom Fixed Installation
: This method is mainly used to install a camera on the close places to the ground like
a wall or a general stand.
Besides there are many other methods to install a camera, but they differ slightly from each
other according to installation places and operation methods. Therefore, please consult
with the installer about the detailed installation methods.
Users can control the alarm systems like a siren, an
Alarm Input 1
alarm and a warning light through two alarm inputs.
Alarm Input 2
For technical support necessary to use the alarm
Alarm Output
function, please contact the installer.
A stable power supply is required for the normal operation. The
adapter with DC 12V/300mA or more is provided basically. It is
recommended to use it along with an uninterruptible power supply
(UPS) device regardless of its polarity.
It connects the network camera in sources of electricity. When
pressing reset buttons during 5 seconds, it starts a rebooting.
When pressing reset buttons during 10 seconds, it starts a factory
reset.