Alarm Setting - Mitsubishi Electric NM-C110 Installation And Operation Manual

Table of Contents

Advertisement

3.3.3 Alarm Setting

Alarm In Setting
This function enables users to conduct the alarm input/output setting and event setting.
Motion Detection Setting
Motion information is processed by splitting the screen into 64 areas. Each area can
be selected by clicking with the mouse, and green point shown in the selected area.
The area which uses the motion information as an event is shown green point, while
the area which does not use the information is indicated empty.
Enable
Check this item when using the motion information.
-Sensitivity
This sets up the sensitivity for the motion detection.
-Motion dwelling time
This sets up the event dwelling time when a motion occurs. This can be set in the
range of 0 ~ 6 seconds. When an event occurs, the motion icon at the upper right
blinks in red for the preset time period. When another motion occurs during the
motion event, the dwelling time is extended on the basis of the occurring time of the
second event.
-Enable down FPS
This feature decreases frame rate to about 1 FPS when no motion event occurs,
while operates with the frame rate set in this item when a motion event occurs.
- 10 -

Advertisement

Table of Contents
loading

Table of Contents