2.12

Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the
following equation:
(Number of seeks per second = 0.4 / (average latency + average access time))
Idle*
Seek
<3.0 bels (typ)
<3.4 bels (typ)
<3.25 bels (max)
<3.6 bels (max)
Note.
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase
acoustic and power to operational levels.
2.13

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined below:
Test
Electrostatic discharge
Radiated RF immunity
Electrical fast transient
Surge immunity
Conducted RF immunity
Voltage dips, interrupts
12
Description
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
80 to 1,000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @
200 Hz
± 1 kV on AC mains, ± 0.5 kV on
external I/O
± 1 kV differential, ± 2 kV common, AC
mains
150 kHz to 80 MHz, 3 Vrms, 80% AM with
1 kHz sine
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
Momentus 5400.3 SATA Removable Drive Cartridge Product Manual, Rev. D
Performance level
Reference standard
B
EN 61000-4-2: 95
A
EN 61000-4-3: 96
ENV 50204: 95
B
EN 61000-4-4: 95
B
EN 61000-4-5: 95
A
EN 61000-4-6: 97
C
EN 61000-4-11: 94
C
C
B