PROBLEM
Inverter does not
turn on.
9.
SPECIFICATIONS
Model: XI41DU
Maximum Continuous Output .......................................... 410 Watts
Surge Capacity (0.1 second) ........................................... 820 Watts
Optimum Efficiency .................................................................. 85%
No Load Current Draw ........................................................... <0.5A
Output Frequency .........................................................60Hz ± 3Hz
Output Wave Form ...........................................Modified Sine Wave
Input Voltage Range........................................... 10.5V – 15.5V DC
Low Battery Alarm ......................................Audible, 11V ± 0.3V DC
Low Voltage Shutdown...............................Under 10.5V ± 0.3V DC
High Voltage Shutdown ................................Over 15.5V ± 0.5V DC
REASON
Poor contact at
terminals
Fuse is blown.
Inverter may be
defective.
• 10 •
SOLUTION
Check for poor
connection to battery
or power supply.
Make sure connection
points are clean. Rock
clamps back and forth
for a better connection.
A blown fuse is
usually caused by
reverse polarity or
a short circuit within
the inverter.
To replace, contact
a qualified service
technician who will
diagnose the inverter
and replace the fuse(s)
with the appropriate
replacement(s).
See warranty and call
Customer Service
1-800-621-5485
(Hours 7:00 am to
5:00 pm CST).