Dial test point
Comment
0
DC power Supply
1
DC power Supply
2
DC power Supply
3
DC power Supply
4
I-Mark Sensor Level
5
Gap sensor Level
Voltage
Voltage Range
+5.0 VDC
+4.8V to +5.2V
+2.0 VDC
+1.9V to +2.1V
+3.3 VDC
+3.1V to +3.5V
+24.0 VDC
+23.5V to +24.5V
Low level (Set the blank area
on the sensor) = A
High level (Set the I-mark
on the sensor) = B
High level - Low level =
A - B = more than +0.9V
Low level (Set the label backing liner or the
centre hole [in case of the centre hole tag]
on the sensor) = C
High level (Set the label or
tag on the sensor) = D
High level - Low level =
C - D = more than +1.0V
EZ Manual: M-8400RVe
Electric Checks and Adjustments
Chart 1
Check pin on TP Test Module and Main PCB
CH3A(+5.0V) - CH1A(GND)
CH4A(+2.0V) - CH1A(GND)
CH5A(+3.3V) - CH1A(GND)
CH6A(+24.0V) - CH1A(GND)
CH1B(+8.4V) - CH1A(GND)
CH2B - CH1A(GND)
3
Adjustment to VR
N/A
N/A
N/A
N/A
VR5
VR4
<