Changing The Cli Prompt; Basic Command; Command Options; Example Command And Response - HP StorageWorks MSA1000 Software Manual

Modular smart array command line interface user guide
Hide thumbs Also See for StorageWorks MSA1000:
Table of Contents

Advertisement

Changing the CLI prompt

To temporarily change the CLI prompt from the default of "CLI>":

Basic command

set prompt <new_prompt>

Command options

new_prompt—the user-defined name for the prompt (up to 24 alphanumeric characters).

Example command and response

CLI> set prompt MSA-1
MSA-1>

Updating MSA firmware

Periodically, HP releases updated versions of MSA controller firmware. Updates may include: additional
features and functions, performance enhancements, and fixes to known issues. In addition to MSA1000
and MSA1500 components, this command can also be used to update components on attached MSA20
storage enclosures.
NOTE:
Because this updating method uses an out-of-band serial connection to the MSA, it is substantially
slower than in-band Fibre Channel updating methods.
If possible, HP recommends using the Fibre-Channel updating method for your operating system.
Operating system
Windows ProLiant host
Linux ProLiant host
HP-UX host
OpenVMS host
Tru64 UNIX host
CAUTION:
Before using this method to update the firmware, make note of the following requirements:
A full backup of all data on the MSA array being updated is required.
A copy of the array configuration, including all the information used to create the units, is needed for
the update.
If it has been more than six months since you restarted your MSA storage system, HP recommends that
you power-cycle the MSA (power off, and then power on) before updating the firmware to ensure that
you are working with a fresh system.
The MSA must be power-cycled after updating the firmware to activate the new firmware.
When performing an online update for active/passive configurations, ensure that the front-right
controller is the active one. The firmware update may not work properly if the front-left controller is
active during the update, especially if the update is performed via serial cable.
Existing firmware on MSA1000 controllers must be v4.32 or higher.
Existing firmware on MSA1500 controllers must be v4.94 or higher.
Host computer must support the 1k Xmodem (Ymodem) protocol.
Because firmware updates require a restart of the MSA and its attached storage enclosures, perform
MSA controller firmware updates only during a scheduled maintenance window.
In-band utility
(Fibre Channel)
MSA Flash Utility
MSA Flash Utility
SCSI Command Utility (SCU)
Array Configuration Utility CLI
(ACU-CLI)
MSA_Util
SCSI CAM Utility (SCU)
HP StorageWorks 1000/1500 Modular Smart Array Command Line Interface user guide
Out-of-band utility
(Serial)
MSA CLI
MSA CLI
MSA CLI
MSA CLI not tested
MSA CLI not supported
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks msa1500

Table of Contents