[c] AM-150BWF
APPROXIMATE
ICE PRODUCTION
PER 24 HR.
lbs./day (kg/day)
APPROXIMATE ELECTRIC
CONSUMPTION
Watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day (m
/day)
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG (kg/cm
G)
SUCTION PRESSURE
2
PSIG (kg/cm
G)
TOTAL HEAT OF REJECTION
Note: The data without *marks should be used for reference.
Ambient
Temp. (°F)
50
70
150 (68)
80
150 (68)
90
145 (66)
100
145 (66)
70
560
80
560
90
560
100
560
70
186 (0.70)
80
186 (0.70)
90
188 (0.71)
100
190 (0.72)
70
14
80
14.5
90
15
100
15
70
3
80
3
90
2.5
100
2.5
70
266 (1.84)
80
268 (1.85)
90
270 (1.86)
100
270 (1.86)
70
65 (0.45)
80
67 (0.46)
90
67 (0.46)
100
67 (0.46)
2720 BTU/h (AT 90°F /WT 70°F)
37
Water Temp. (°F)
70
140 (64)
130 (60)
140 (64)
130 (60)
140 (64)
130 (60)
135 (62)
125 (58)
560
560
560
570
560
570
570
225 (0.85)
524 (1.98)
234 (0.89)
550 (2.08)
239 (0.90)
587 (2.22)
246 (0.93)
610 (2.31)
15
16.5
15
16.5
15
16.5
15.5
17
3
2.5
2.5
2.5
2.5
2.5
2.5
2.5
270 (1.86)
274 (1.89)
270 (1.86)
274 (1.89)
271 (1.87)
274 (1.89)
271 (1.87)
274 (1.89)
64 (0.44)
64 (0.44)
65 (0.45)
65 (0.45)
67 (0.46)
65 (0.45)
65 (0.45)
65 (0.45)
90
570