4. BIN CONTROL THERMOSTAT

Bin Control Thermostat Replacement Procedure
To ensure proper operation, follow the instructions below:
1) Make a 40 mm (1.6") diameter loop.
2) Locate the loop below the Thermostat Capillary (Bulb).
3) Manually bend the Capillary to keep it 15 mm (0.6") forward from the through hole
position on the Holder.
4) Turn up the end of the Capillary.
Through Hole
Loop
40 mm (1.6") DIA
Bin Control Thermostat Assembly Details
Flexible Tube
[NOTE]
1) Run Cord Heater along with Capillary of Thermostat and bind them tightly with
Aluminum Tape (Form end to end of Cord Heater).
2) Do not overheat Flexible Tube during shrinking process.
Thermostat
Cord Heate
15 mm (0.6")
Capillary (Bulb)
Silicone Tube
Silicone Tube
DETAIL A
25
Holder
Capillary (Bulb) End
210mm (8.3")
Seal
Capillary (Bulb)
A
150mm