4. Installation

Fig.4-1
ArtNo.600-0034 - Clearances
Fig.4-2
���
���
��������������������
ArtNo.600-0033 - Door clearances
Fig.4-3
ArtNo.600-0009 - Removing the door
ArtNo.600-0011 - Disconnecting the pipes
Fig.4-4
Fig.4-5
�����������������
�������������
ArtNo.600-0047 -
DxD water connector
���������������
�������������
�����������������
����
��
��
���
ArtNo.600-0048 -
DxD water connector 2
Positioning Your Appliance
Choosing the Right Location
This appliance should be installed in a room that is dry
and well ventilated. To ensure adequate ventilation, the
refrigerator should be at least 15 mm clear on all sides
from kitchen cabinetry (Fig.4-1). Any units placed above
the appliance must be clear by 15mm to allow sufficient
ventilation.
If locating the refrigerator close to a corner, sufficient spacing
must be left for opening the doors and removing the shelves
(Fig.4-2).
This appliance should be at least 100 mm from any electric
or gas cooker and 300 mm from any coal or oil stove. If this is
not possible, ensure that appropriate insulation is used.
Avoid exposing the appliance to direct sunlight, and sources
of heat (such as radiators, heaters or cookers).
If this appliance is situated in a cold environment (such as
a shed, outhouse or garage) it will affect its performance.
You may find that the performance of the appliance is not
consistent and this may damage foods. A consistent ambient
temperature of 10 °C or above is recommended.
Removing and Installing the Doors and
Drawers
In the event that you need to remove the
refrigerator doors, please follow the door removal
and installation instructions below.
It is suggested, for your safety, to have two or more
people to assist you in completing the below task to
avoid injury, product damage or property loss.
Door Removal and Installation
Undo the retaining screws on the top cover. Remove the top
cover and place to one side for reinstallation.
Right-hand door
Using a suitable screwdriver, remove the top hinge screws
and remove the hinge. Lift the refrigerator door off the lower
hinge (Fig.4-3) and place it to one side.
Refit the door and cover in the reverse sequence.
Left-hand door
Disconnect the wire cable connector (Fig.4-4) above the left-
hand hinge.
Fig.4-6
Fig.4-6
On the back of the appliance, remove the water pipe cover.
Pull the upper securing clip off the water connector (Fig.4-5).
Push down on the top of the connector to release the water
pipe (Fig.4-6) and remove.
From the top of the left-hand door, pull out the water pipe
until it is clear of the refrigerator body.
Using a suitable screwdriver, remove the top hinge screws
and remove the hinge. Lift the refrigerator door off the lower
hinge and place it to one side.
10