Electrical Information

A. Recommendation for Wire
This appliance requires 110-120 VAC be wired to the
junction box either for use of optional accessories or for
proper operation of the appliance.
Note: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition or the Canadian Electric Code, CSA C221.1.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when it is
installed in locations such as in bathrooms or near sinks.
B. Connecting to the Appliance
WARNING
Wire 110V to electrical junction box.
Do NOT wire 110V to valve.
Do NOT wire 110V to wall switch.
• Incorrect wiring will damage millivolt valves.
• Uninterrupted or continuous power is required
at all times in IPI system EXCEPT when using
battery back-up.
• Incorrect wiring will override IPI safety lockout and may
cause explosion.
WIRES WITH LABEL "FOR USE WITH REMOTE OR WALL SWITCH ONLY"
(LOCATED UNDER FIREPLACE)
ORANGE
IPI
VALVE
FLAME
SOLENOID
ADAPTER WIRES
Figure 10.1 IntelliFire Pilot Ignition (IPI) Wiring Diagram
GREEN
GROUND
BLACK
1
2
IPI
3
4
MODULE
5
6
7
8
RED
FLAME ON
RED
FLAME HIGH/LOW
AC
PLUG
FIREBOX LIGHTS
BLACK
WHITE
GROUND
CONTINUOUS
110VAC
SUPPLY
Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11
C. IntelliFire Ignition System Wiring
This appliance requires a 110 VAC supply to the appli-
ance junction box for operation. A wiring diagram is shown
in Figure 10.1.
This appliance is equipped with an IntelliFire control valve
which operates on a 3 volt system.
This appliance is supplied with a battery pack and a 3 volt
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junc-
tion box be installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries (not includ-
ed). Batteries cannot be placed in the battery pack while
using the 3 volt AC transformer. Conversely, the trans-
former must be unplugged if the battery pack is used.
Battery polarity must be correct or module damage will
occur.
BATTERIES
RED
BLACK
YELLOW (HNG)
WHITE (HTL)
BATTERY
IPI PILOT
G
Y
BROWN
BROWN
BROWN
BROWN
RED
3V DC
BLACK
ORANGE
ORANGE
BLACK
BLACK
GROUND
PIGTAIL
AUX
GREEN
CONNECTION
HOT
NEUTRAL
CAUTION
RED
REAR VIEW
GREEN
R
FRONT VIEW
YELLOW
FACTORY
CONNECTED
YELLOW
TOGETHER
FAN THERMOSTAT
FAN
CONNECTION
Note 1: Ignition module, valve, pilot
and wall switch operate on 3 volts.
Note 2: Plug QWSK-MLT wall switch
kit into the REM/AUX outlet on the
junction box.