1' MIN. (305mm)
2' MIN. (610mm)
3' MIN. (914mm)
4' MIN. (1.22m)
V+H=40' MAX. (12.4m)
H = 8' MAX. (2.4m)
Use D-Series components only.
Note: There MUST be a 25% reduction
in total H when using flex vent, except
when using the simple up and out
installation (see Figure 9).
Figure 12. Venting with One 90° Elbow
Use SL D-Series
components only.
VENTING WITH ONE (1) 90
V (MIN.)
90
o
Elbow on Top
1 FT (305mm)
2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
5 FT (1.52m)
H MAX. = 16 FT (4.8m)
VENTING WITH ONE (1) 90
V (MIN.)
90
o
Elbow on Top
1 FT (305mm)
2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
5 FT (1.52m)
H MAX. = 16 FT (4.8m)
Figure 13. Venting with One 90° Elbow
H
2' MAX. (610mm)
4' MAX. (1.22m)
6' MAX. (1.86m)
8' MAX. (2.4m)
o
ELBOW
NATURAL GAS
H (MAX.)
2 FT (610mm)
3 FT (914mm)
4 FT (1.22m)
6 FT (1.86m)
8 FT (2.48m)
16 FT (4.8m)
V + H MAX. = 40 FT (12.2m)
o
ELBOW
PROPANE
H (MAX.)
NOT ALLOWED
2 FT (610mm)
4 FT (1.22m)
6 FT (1.86m)
8 FT (2.48m)
16 FT (4.8m)
V + H MAX. = 40 FT (12.2m)
V
H
Note: There MUST be a 25% reduction
in total H when using flex vent, except
when using the simple up and out
installation (see Figure 9).
18
H
V