Section 3 − Introduction; Specifications; Welding Power Source Duty Cycle And Overheating - Hobart Welding Products IronMan 210 Owner's Manual

Welding system & gun
Table of Contents

Advertisement

3-1. Specifications

Rated Output
150 A at 23 VDC,
40% Duty Cycle
Wire Type and Diameter
Solid Steel/
Stainless Steel
.023 − .045 in
(0.6 − 1.2 mm)
* While idling

3-2. Welding Power Source Duty Cycle And Overheating

Overheating
SECTION 3 − INTRODUCTION
Max. Open
Circuit
Circuit
200 V
Voltage
33
Aluminum
Flux Cored
.030 − .035 in
.030 − .045 in
(0.8 − 0.9 mm)
(0.8 − 1.2 mm)
40%dutycycle
4 Minutes Welding
0
Minutes
Amps Input at Rated Output, 60 Hz, Single-Phase
230 V
29
25
2.3*
2*
No Load Wire Feed
Speed
90−750 IPM
(2.3−19 m/min)
6 Minutes Resting
15
Reduce Duty Cycle
KVA
5.8
0.4*
Dimensions
Weight
H: 31-1/4 in (794
146 lb
mm)
(66 kg)
W: 18-7/8 in (479
W: 18 7/8 in (479
mm)
D: 36-1/2 in (927
mm)
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
voltage, or duty cycle before
welding.
Y Exceeding duty cycle can
damage
unit
and
warranty.
A or V
OR
duty1 4/95 − 199 211
OM-927 Page 9
KW
4.9
0.1*
void

Advertisement

Table of Contents
loading

This manual is also suitable for:

M-10 gunM-10

Table of Contents