ADJUSTING THE DIRECTION OF AIR CIRCULATION

G Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Control Unit.
G Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airflow-direction louvers have
stopped moving.
Vertical Air Direction Adjustment
Press the SET button (Vertical) (Fig. 6 R).
Each time the button is pressed, the air direction range will change as follows:
1
Types of Air flow Direction Setting:
1,2,3 :
During Cooling/Dry modes
1,2,3,4,5,6 :
During Fan mode
The Remote Control Unit's display does
not change.
G Use the air direction adjustments within the ranges shown above.
G The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry mode : Horizontal flow 1
During Fan mode
G During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 1; the air direction cannot be adjusted during this pe-
riod.
G Direction 1
2
Only the direction of the Air Flow Direction Louver changes; the direction of the
Power Diffuser does not change.
Horizontal Air Direction Adjustment
Press the SET button (Horizontal)(Fig. 6 S).
G Each time the button is pressed, the air direction range will change as follows:
1
2
The remote control unit's
display does not change.
1
En-9
2
3
4
5
1
2
3
4
5
6
: Downward flow 5
3
4
5
2
5
3
4
R DANGER!
G Never place fingers or foreign objects in-
side the outlet ports, since the internal fan
operates at high speed and could cause
personal injury.
6
G Always use the Remote Control Unit's
SET button to adjust the vertical airflow
louvers. Attempting to move them
manually could result in improper op-
eration; in this case, stop operation and
restart. The louvers should begin to
operate properly again.
G During Cooling and Dry modes, do not
move the vertical air direction louvers
outside their proper operating range
for the mode (1 - 3) and into the fan
region (4 - 6); using the louvers in
the fan region will cause moisture to
condense near the air outlet, and wa-
ter may drop onto the floor. During the
Cooling/Dry modes, if the louvers are
operated outside the range 1 - 3 for
more than 30 minutes, they will be
automatically returned to the 3 range.
G When used in a room with infants, chil-
dren, elderly or sick persons, the air
direction and room temperature
should be considered carefully when
making settings.