Polaris PC 100-34 2NV Installation Instructions And Use & Care Manual

Polaris PC 100-34 2NV Installation Instructions And Use & Care Manual

Commercial gas water heater

Advertisement

WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any telephone in your
building.
Immediately call your gas supplier
from a neighbor's telephone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
PRINTED IN U.S.A. 0112
This manual covers model numbers:
Canada
PC 100-34 2NV or 2PV
PC 130-34 2NV or 2PV
PC 130-50 2NV or 2PV
PC 150-34 2NV or 2PV
PC 150-50 2NV or 2PV
PC 175-50 3NV or 3PV
PC 199-50 3NV or 3PV
Note:
The manufacturer of this water heater recommends that it
be professionally installed by trained and qualified service
professionals.
Polaris
Commercial Gas
Water Heater
Installation
Instructions and
Use & Care Guide
To obtain technical, warranty or service assistance during or
after the installation of this water heater, visit our website at:
http://www.gsw-wh.com
or call toll free:
1-888-479-8324
When calling for assistance, please have the following
information ready:
1. Model number
2. 7 Digit product number
3. Serial number
4. Date of installation
5. Place of Purchase
Table of Contents........................................................... 2
INSTALLER:
Affix these instructions to or adjacent to the water
heater.
OWNER:
Retain these instructions and warranty for future
reference. Retain the original receipt as proof of
purchase.
®
322761-000
1

Advertisement

Table of Contents
loading

Summary of Contents for Polaris PC 100-34 2NV

  • Page 1: Water Heater Safety

    This manual covers model numbers: Canada PC 100-34 2NV or 2PV PC 130-34 2NV or 2PV PC 130-50 2NV or 2PV PC 150-34 2NV or 2PV PC 150-50 2NV or 2PV PC 175-50 3NV or 3PV PC 199-50 3NV or 3PV...
  • Page 2: Table Of Contents

    Gas Supply and Piping ............. 17-18 Electrical Connections/Wiring Diagram ........19-20 Installation Checklist ............... 21 Operating Your Water Heater ............22-24 Polaris® Operating Instructions ............23 Maintenance of Your Water Heater ..........24-25 Troubleshooting ..................26 Software Operation Sequence ............. 27 Parts List and Diagram .................
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS Consumer Information A data plate identifying your water heater can be found on the front of the heater. When referring to your water heater, OBSERVE ALL GOVERNING CODES AND ORDINANCES. always have the information listed on the data plate readily This water heater is design-certified by CSA International available.
  • Page 4: Location Requirements

    the termination with a minimal length and number of elbows. Input rates are reduced as vent system length increases. The venting system must comply with the requirements set forth in the venting section of this manual. • Locate the water heater near the existing gas piping. If installing a new gas line, locate the water heater to minimize the pipe length and elbows.
  • Page 5: Condensate Line

    Clearances and Accessibility CONDENSATE LINE Notice: Minimum clearances from combustible materi- Important: Do not run the condensate drain in areas als are stated on the data plate located on the front of the that are likely to freeze. Frozen condensate will block the water heater.
  • Page 6: Vent Pipe System

    When installing the drain line, note the following: accordance with CAN/CSA-B149.1-current edition. • Plastic pipe or tubing must be used to connect the When replacing an existing Polaris ® unit, it is recommended condensate drain to a suitable drain or condensate that the venting system be reviewed for compliance with pump.
  • Page 7: Intergrated Filter Installation

    Integrated Filter Installation Figure 4A: Remove Plastic Cap When installing the adaptor rubber boot, note the following: • Remove and discard the plastic cap from the outer clamshell housing (see figure 4A). • To connect the heater to the air inlet, use the vent adaptor rubber boot provided in the base skirt.
  • Page 8: Vent Pipe Material

    Vent Pipe Material All pipe, fittings, pipe cement, primers and procedures must conform to American National Standard Institute and American Society for Testing and Materials (ANSI/ASTM) Combustion Air Inlet Piping; The following plastic standards in the United States. This water heater has been materials may be used for combustion air inlet piping.
  • Page 9 Vent Termination Locations 1. Use only 2 inch pipe or a 2 inch concentric vent on the vent termination for 100,000 - 150,000 BTU/ Hr models. Do not expose any 3” X 2” reducers or The air inlet and exhaust outlet must be installed with the bushings to outdoor ambient temperatures.
  • Page 10: Vent Terminations

    Note: See “Venting Additional Polaris ® Units” on Page 11 coupling to prevent the pipe from being pushed back into the for correct terminations if installing more than one Polaris ® structure. The standard horizontal exhaust outlet termination gas water heater.
  • Page 11: Vertical Terminations

    Minimum Above Grade To Keep Terminal Openings Above Anticipated Snow Levels. ® Venting Additional Polaris Units When using three or more Polaris units, install vent ® terminations per Method C or Method D: ® When using two (2) Polaris units, install vent terminations...
  • Page 12 12” (30.5cm) Minimum Figure 13E, 13F, 13G clearance above anticipated snow level. 24” (61cm) Max. 36” (.9144 m) Min. Note: For installation of more than two Polaris units, ® follow the pattern established in Method G. 2” (5.08 cm) Max.
  • Page 13: Gas Input Rate

    100k, 130k, and 150k models is shown in figure 14. WATER PIPING SYSTEM Piping Installation 6. The Polaris gas water heater is shipped with a factory- ® installed Temperature and Pressure Relief Valve. Piping, fittings, and valves should be installed according to Install a discharge line in the opening in the T &...
  • Page 14: General Information

    Adequate Drain Mixing Valve Installation Closed System/Thermal Expansion A mixing valve has been provided for use with the Polaris ® Gas water heater and must be installed, per the As water is heated, it expands (thermal expansion). In a manufacturer’s instructions, in the domestic hot water line.
  • Page 15: Storage Tank Installation

    Do not use with piping that has been treated with chromates, boiler seal or other chemicals and do not When installing the Polaris® with a storage tank, see figure add any chemicals to the water heater piping. 18 for piping suggestions.
  • Page 16: Relief Valve

    Notes on Figure 18: Figure 18: Polaris with Auxillary Storage Tank - One or Two ® Temperature System (With or Without Building Recirculation) If tank temperature is set above 120°F (48.9°C) and water is sup- plied for domestic use (hand wash- ing, showering, etc.) a mixing valve...
  • Page 17: Gas Supply And Piping

    GAS SUPPLY AND PIPING Figure 19: Gas Piping Installation Explosion Hazard Use a new AGA or CSA approved gas supply line. 3” (7.62 cm) Minimum Install a shut-off valve. Do not connect a natural gas water heater to a L.P. Gas Supply. Gas Pressure Do not connect an L.P.
  • Page 18: Gas Pressure Testing

    Gas Pressure Testing Important: This water heater and its gas connection must be leak tested before placing the appliance in operation. If the code requires the gas lines to be tested at a • pressure of 14” W.C. (3.486 kPa) or greater, the water heater and its manual shut-off valve must be discon- nected from the gas supply piping system and the line capped.
  • Page 19: Electrical Connections/Wiring Diagram

    ELECTRICAL CONNECTIONS 4. Connect this circuit (directly from the electrical service box) to an electrical disconnect switch. 5. Ground the water heater by connecting the electrical Electrical Shock Hazard service ground wire to the green ground wire (provided). Disconnect power before Note: The power supply to this water heater must be servicing.
  • Page 20: Wiring Diagram

    WIRING DIAGRAM HEATER SUPPLIED WITH T92 SERIES RELAY Figure 20A NEUTRAL TO 120/60 FUSED BLOWER BLUE POWER SUPPLY DISCONNECT BLACK WHITE N.O. BLOWER WHITE BLACK GREEN RELAY BROWN WHITE BLACK/WHITE RELAY COIL GROUND NEUTRAL (WHITE) GREEN TO 120/60 GREEN IGNITION POWER IGNITER SUPPLY...
  • Page 21: Installation Checklist

    INSTALLATION CHECKLIST Water Heater Location Alternate Horizontal Correct relationship - outlet to inlet. Requirements 12” Min. (30.5 cm) above anticipated snow level. 2” exhaust outlet/air inlet pipe sloped down towards Centrally located with the water piping system. Located water heater at 1/4” per foot (21 mm per meter). 3” as close to the gas piping and vent pipe system as pos- piping sloped down towards the heater at 1/8”...
  • Page 22: Operating Your Water Heater

    OPERATING YOUR WATER HEATER Read and understand these directions thoroughly before When the thermostat calls for heat, the blower will run for attempting to operate the water heater (see Operating 6 seconds to purge the system of any accumulated gas or Instructions on Page 23).
  • Page 23: Polaris® Operating Instructions

    * Temperatures shown are approximates and may vary. Stacking occurrence of igniter failure due to excessive condensate. Important: A mixing valve (provided) must be installed in Stacking occurs when a series of short draws of hot water the hot water outlet to reduce the risk of scald injury when (3 gallons [11.3 liters] or less) are taken from the water setting the thermostat in excess of 120°F (48.9°C).
  • Page 24 OPERATIONAL CONDITIONS Figure 23: Drain Valve Access Water Heater Sounds During the normal operation of the water heater, sounds or noises may be heard. These noises are common and may result from the following: 1. Normal expansion and contraction of metal parts during periods of heat-up and cool-down.
  • Page 25: Maintenance Of Your Water Heater

    MAINTENANCE OF YOUR WATER HEATER 3 Month Inspection Replacing the Gas Valve Important: The rubber gasket that seals the gas valve to At least every 3 months, a visual inspection should be the venturi manifold must be used (previous gaskets may made of the combustion air inlet as well as the exhaust and be reused, if in good condition).
  • Page 26: Troubleshooting

    TROUBLESHOOTING Table 5: Ignition Control Module (ICM) LED Error Codes: (Flashes visible through viewport in access door) FLASHES INDICATED PROBLEM CONTROL REACTION Pressure Switch Closed Pressure Switch Open Failed Ignition Gas Valve Hardware Fault Flame Sense Hardware Fault False Flame SL** Ignition Control Hardware Fault Ignition Control Software Fault...
  • Page 27: Software Operation Sequence

    SOFTWARE OPERATION SEQUENCE IGNITION CONTROL MODULE SOFTWARE OPERATION SEQUENCE...
  • Page 28: Parts List And Diagram

    REPAIR PARTS LIST/DIAGRAM When ordering repair parts always give the following information: Model, serial, and product numbers Type of gas Item number Parts description Repair Parts List ITEM PARTS DESCRIPTION 1” NPT x 2.5” BRASS NIPPLE THERMOSTAT SENSOR BUSHING O-RING THERMOSTAT SENSOR/ECO INVERTED FLARE NUT PLUG...
  • Page 29: Polaris ® Models And Dimensions

    POLARIS MODELS & DIMENSIONS Figure 26 Table 6: Length in inches (meter) INPUT WATER T&P INLET/EX- GAL. APPROX MBTU VENT EXTERIOR CONNECTIONS SUPPLY HAUST MODEL SHIP. (Liter) PER HR. DIA. NUMBER CAP. WEIGHT (Kilowatt) INCHES PC 100-34-2NV OR 2PV 2 OR 3...
  • Page 30 NOTES...
  • Page 31 NOTES...
  • Page 32 Polaris ® Commercial Gas Water Heater GSW Water Heating 599 Hill Street West Fergus, ON Canada N1M 2X1 Should you have any questions on obtaining technical, warranty or service assistance during or after the installation of this water heater, email us at: techsupport@gsw-wh.com...
  • Page 33 Appeler www.johnwoodwaterheaters.com www.gsw-wh.com site notre visiter techsupport@gsw-wh.com à courriel envoyer nous veuillez chauffe-eau, l’installation après pendant l’entretien garantie à relatifs renseignements technique, assistance d’une l’obtention concernant questions avez vous Canada Fergus, West Street Hill Heating Water commercial Chauffe-eau Polaris ®...
  • Page 34 REMARQUES...
  • Page 35 REMARQUES...
  • Page 36 (mètres) Longueurs HAUT AVANT GAUCHE CÔTÉ condensat vidange Connexion d’évacuation additionnels Soupape Alimentation d’air Sortie latéraux Bacs Arrivée Connexion froide froide d’eau Entrée d’eau Entrée d’air Arrivée température chaude d’eau Sortie d’évacuation réglage Sortie Bouton Soupape Figure POLARIS DIMENSIONS MODÈLES...
  • Page 37 VENTILATEUR D’ISOLATION RELAIS illustré) (non VENTURI D’ÉTANCHÉITÉ JONT POTENTIOMÈTRE VIDANGE SOUPAPE THERMIQUE SÉCURITÉ À DÉCHARGE SOUPAPE FROIDE D’EAU TUBE ENSEMBLE 80mm) CONDENSATION D’EAU PURGEUR ENSEMBLE 50mm) CONDENSATION D’EAU PURGEUR ENSEMBLE TRANSFORMATEUR D’ALLUMAGE COMMANDE THERMOSTAT CARTE TEMPÉRATURE SÉLECTEUR BOUTON 5/16 9/32 COMBINAISON À...
  • Page 38 SECONDES. PENDANT VENTILATEUR ARRÊTER PERMANENT. VERROUILLAGE SECONDES? BOUT FERMÉ EST-IL MANOSTAT MINUTES APRÈS RÉINITIALISATION – TEMPORAIRE VERROUILLAGE SECONDES INTER-PURGE FLAMME. AUCUNE L’ALLUMAGE) POUR TOTAL ESSAIS SAVOIR (À SÉQUENCE? ÉTAIT-CE ÈME FERME MANOSTAT APRÈS SECONDES PRÉ-PURGE TENTATIVE? ÈME OUVERT? VÉRIFICATION) ÉTAIT-CE MANOSTAT RAISON INITIAL...
  • Page 39 d’allumage commande module Remplacer extrémités? deux filage Corriger connecté brûleur terre à mise Est-ce dépannage. d’air d’arrivée filtre nettoyer Vérifier • défectueux Manostat • secondes? après s’éteint rouge Est-ce étanche manostat Tube • cesse? chaleur demande bloquée Ventilation • secondes? jusqu’à...
  • Page 40 Bride torique Joint pression Prise caoutchouc Rondelle fixation. niveau quatre enlevant régulateur l’arrivée côté bride Enlever TORX T-25 gaz. régulateur avec caoutchouc rondelle gardant l’unité régulateur Retirer Figure 6903775.) pièce numéro VK8115V, (modèle régulateur trousse avec fournie Torx T-25 clé www.techsupport@gws-wh.com.
  • Page 41 réservoir. fuite avec confondre remplissage; pendant former peut condensation IMPORTANT ». chauffe-eau Fonctionnement « section consignes conformément marche chauffe-eau remettre réservoir, remplir d’accès, porter replacer vidange, robinet Fermer sédiments. éliminer pour réservoir Rincer réservoir. l’eau toute vider pour chauffe-eau vidange robinet Ouvrir bâtiment.
  • Page 42 autorisé. service à chauffe-eau régler cas, certains dans toutefois, technicien examiné soit celui-ci avant °F); (130 °C 54,4 préféré départ point désiré. réglage chauffe- fonctionner faire froide. d’alimentation température cadran déplaçant réglée être peut robinet fermer l’unité à électrique l’alimentation Couper l’eau température...
  • Page 43 CESSE CHALEUR DEMANDE SECONDES JUSQU’À APPROX. VENTILATEUR FONCTIONNE CHAUFFE-EAU PRÉPURGE ALLUMÉE PRINCIPAL JAUNE BRÛLEUR LUMIÈRES ALLUMÉE CHALEUR ROUGE DEMANDE THERMOSTAT S’OUVRE ALLUMÉE ohms °C °F RÉGULATEUR VERT FONCTIONNE, VENTILATEUR ohms °C °F ohms °C °F SECONDES L’UNITÉ À APPLIQUÉE APPROX L’ALLUMEUR ohms °C...
  • Page 44 CAN/CSA-B149.1. cours l’édition à conformément effectuées être doivent canadiennes installations 54). etc. fenêtres, évents, autres coins, Loin (NFPA Z223.1 ANSI », chauffage national Code « cours l’édition à ceux-ci, l’absence locaux pi). (1/8 mètre 10,5 à chauffe-eau codes applicables dispositions conformément Installé...
  • Page 45 ÉQUIVALENT. CALIBRE 105C TYPE TERRE REMPLACÉ ÊTRE DOIT REMPLACÉ, ÊTRE DOIT SEULEMENT THERMOSTAT CHAUDE L’APPAREIL, AVEC FOURNI CELUI THERMOSTAT CADRAN INFÉRIEUR CADRAN D’ORIGINE, FILS L’UN AVIS THERMOSTAT CARTE (N.O.) ORANGE ROUGE OUVERT TERRE NORMALEMENT JAUNE ORANGE THERMOSTAT PRESSOSTAT CAPTEUR BLEU VERT JAUNE RELAIS...
  • Page 46 Replacer jusqu’à (blanc) neutre connecteur voltes terre jusqu’à (noir) chaud connexion voltes [120 polarisée, bien être réparation. toute avant doit chauffe-eau à électrique L’alimentation Remarque électrique l’alimentation Couper (fourni). électrique choc Risque vert terre à...
  • Page 47 incendie. explosion mort, entraîner peut faire défaut autorisés. d’entretien gaz. tuyauterie l’installation après tuyaux purger doit qualifié service technicien initiale. marche employés gazière société autorisés mise lors veilleuse l’allumage d’empêcher risque employés agréés, chauffage personnel l’air contenir peuvent tuyaux Remarque incluent qualifiée personne...
  • Page 48 approuvée. méthode autre toute fuite) indiquent forment bulles (les l’eau chlorure sans savon Utiliser fuites. s’il vérifier l’alimentation Ouvrir facile. plus l’entretien rendre pour Ceci manuel. d’arrêt robinet chauffe-eau entre rodé joint à raccord Installer d’eau. gouttelettes étrangères matières saletés, recueillir pour longueur...
  • Page 49 Robinet chaude d’eau Sortie mélangeur etc.), douche, mains, Thermomètre Thermomètre (lavage résidentiel usage pour fournie l’eau (120°F) 48,9°C à réglée réservoir température bâtiment) recirculation sans (avec températures deux à Système auxiliaire stockage réservoir avec Polaris Figure Figure Notes ®...
  • Page 50 • chauffe-eau. tuyauterie. suggestions pour Figure consulter tuyauterie à chimique produit aucun n’ajouter stockage, réservoir avec Polaris l’installation Lors ® chimiques produits autres chaudière joints chromates, stockage réservoir Installation avec traitée été tuyauterie avec l’utiliser •...
  • Page 51 Dans thermique). Voir résidentielle. chaude d’eau conduite dans fabricant, (dilatation augmente volume chauffée, l’eau Lorsque instructions selon installé être doit Polaris ® thermique chauffe- avec utilisé soit qu’il afin fourni été mélangeur fermé/dilatation circuit Système mélangeur Installation adéquat Drain 15,2 métallique...
  • Page 52 Installer être doivent robinets soupapes raccords, tuyaux, l’usine. à installés thermique sécurité soupape tuyauterie Installation reniflard avec expédié Polaris® chauffe-eau D’EAU CONDUITE RÉSEAU ventilation Longueur Figure à illustrée 150k 130k, 100k, modèles pour approximative maximum/minimum production circulation. carneau combustion l’air...
  • Page 53 Ventilation Min. 0,9144 Max. 5,08 méthode à établi modèle suivez 45° Coude Polaris® unités deux plus l’installation Pour Remarque Support Min. 0,9144 Max. prévu. neige toit Fourreau/solin niveau au-dessus combustion 30,5 minimum Dégagement Évacuation 13F, 13E, Figure Max. toit travers à...
  • Page 54 Entrée Max. Évacuation Max. Max. Évacuation Évacuation Max. Figure Minimum 91,4 ci-dessous indiquées Méthode Méthode utilisant ventilation terminaisons Figure installer Polaris unités deux l’utilisation Lors ® Polaris Méthode ® Méthode utilisant ventilation terminaisons additionnelles d’unités Ventilation installer plus, Polaris unités trois l’utilisation...
  • Page 55 Évacuation Max. standard horizontale Terminaison Figure d'entrée/sortie emplacements dimensions connaître pour à reporter d’air Arrivée d’évacuation Sortie Max. tuyau soutien Polaris chauffe-eau d’un plus installer ® Bande voulez vous terminaisons bonnes connaître pour page à » Polaris additionnelles d’unités Ventilation «...
  • Page 56 gaz. fournisseur exigences locaux d’installation codes conforme Dégagement horizontalement. dedans mécanique mécanique. d’alimentation entrée d’une dessus d’alimentation entrée d’une 1,83 Dégagement appareil autre tout appareil autre tout vers combustion d’air l’arrivée bâtiment mécanique vers combustion d’air l’arrivée bâtiment mécanique d’alimentation Dégagement d’alimentation Dégagement...
  • Page 57 plus. (51,29 BTU/Hr 175,000 entrée pour utilisé être doit tuyau tuyaux) alternatif Horizontal seulement. 43,9 (29,3, BTU/HR 150,000 130,000 100,000, entrée ayant modèles avec utilisé être peut tuyau tuyaux) standard Horizontal côté. coude avec tuyau minimale longueur 90°. à coude à...
  • Page 58 filtre support Retirer extérieure coque double Boîtier filtre. support noir caoutchouc support surface silicone graisse l’adaptateur installé. soit filtre support couche fine appliquer intérieure, coque caoutchouc double boîtier extérieure coque Manchon sans utilisé être jamais doit chauffe-eau Remarque double boîtier réattacher difficile S’il...
  • Page 59 à pompe existant, Polaris® appareil d’un remplacement Lors approprié drain à condensat drain connecter pour utilisé être doit plastique tube conduite • CAN/CSA-B149.1.
  • Page 60 collée vidange vidange tige Joint torique Joint té Rondelle Ensemble coller puis besoin inoxydable selon Orienter d’évacuation Tube condensation d’eau purgeur Ensemble coulissant Écrou l’entretien pour Min. 10,2 Côtés DESSUS condensation d’eau purgeur Installation Figure l’entretien pour Min. Avant Ventilation chauffe-eau.
  • Page 61 réseau chauffe-eau. l’emplacement choisir moment d’arrivée ventilation d’air d’évacuation réseau tuyauterie exigences compte Tenir • fabricant. instructions conformément ventilés installés soient appareils condition à bain, salle signalétique. plaque inscrites dégagement valeurs chambre donnant porte avec armoire Observer d’entretien. d’utilisation fins accessibles dans installé...
  • Page 62 chauffe-eau. installer faire pour qualifié technicien d’un services retenir doit directives, suivre à difficulté s’il chauffe-eau correctement installer pour nécessaires compétences possède l’acheteur manuel. présent fonctionnement d’installation directives conformer défaut attribuable décès blessure dommage, quelque à relativement responsabilité aucune n’assument chauffe-eau vendeur fabricant...
  • Page 63 ............Polaris dimensions Modèles ® ............pièces diagramme Liste ..........logiciel fonctionnement Séquence .................... Dépannage 24-25 ..............chauffe-eau Entretien ..............Polaris® d’utilisation Mode 22-24 ............chauffe-eau Fonctionnement ........... l’installation relative contrôle Liste 19-20 ......électriques câblage/Connexions Schéma 17-18 ........tuyauterie...
  • Page 64 AVERTISSEMENT d’installation Instructions Polaris ® commercial Chauffe-eau qualifiés. formés service professionnels installé soit chauffe-eau recommande chauffe-eau fabricant Remarque 199-50 175-50 150-50 150-34 130-50...

Table of Contents