Safety Rules
WARNING
4. LOCATE the furnace out of traffic patterns as much as
READ THESE RULES AND THE INSTRUCTIONS
CAREFULLY.
FAILURE
TO FOLLOW
THESE
RULES AND INSTRUCTIONS
COULD CAUSE A
MALFUNCTION OF THE FURNACE. THIS COULD
RESULT IN DEATH, SERIOUS BODILY INJURY,
AND/OR PROPERTY DAMAGE.
possible
with a minimum
of 6" clearance
from all
combustible walls and 15" on two adjoining sides of the
grille for passage.
5. BE SURE to provide
for adequate
combustion
and
ventilation air. The flow of this air to the furnace must not
be blocked.
INSTALLATION MUST CONFORM TO LOCAL CODES. IN
THE ABSENCE OF LOCAL CODES, INSTALLATION MUST
CONFORM WITH THE NATIONAL FUEL GAS CODE, ANSI
Z223.1.
INSTALLATION
AND REPAIR SHOULD BE DONE BY A
QUALIFIED
SERVICE
TECHNICIAN.
THE CLEANED
FURNACE SHOULD BE INSPECTED
BEFORE USE AND
AT LEAST ANNUALLY
BY A PROFESSIONAL
SERVICE
TECHNICIAN.
MORE FREQUENT
CLEANING
MAY BE
REQUIRED
DUE TO EXCESSIVE
LINT FROM SOME
CARPETING,
BEDDING
MATERIAL,
ETC.
IT IS
IMPERATIVE
THAT
CONTROL
COMPARTMENTS,
BURNERS AND CIRCULATING
AIR PASSAGEWAYS
OF
THE FURNACE BE KEPT CLEAN.
YOUNG
CHILDREN
SHOULD
BE
CAREFULLY
SUPERVISED
WHEN THEY ARE IN THE SAME ROOM
WITH THE FURNACE.
6. USE joint compound (pipe dope) on threaded joints of gas
piping that is resistant to the action of liquefied petroleum
gas.
7. USE only ground joint unions in gas piping.
8. INSTALL a manual shutoffvalve and union ahead of the
controls so that the controls and furnace may be removed
for servicing, if necessary.
9. INCLUDE a 1/8 NPT plugged tapping accessible for test
gauge connection
immediately
upstream
of the gas
supply connection to the furnace.
10. NEVER test for gas leaks with an open flame. Use soap
suds to check all gas connections.
This will avoid the
possibility of fire or explosion.
11. INSTALL the furnace to a proper venting system
ANY SAFETY SCREEN, GUARD OR PARTS REMOVED
FOR SERVICING AN APPLIANCE
MUST BE REPLACED
PRIOR TO OPERATING
THE APPLIANCE
TO AVOID
PROPERTY DAMAGE, BODILY INJURY OR DEATH.
12. DO NOT place clothing or other flammable material on
or near furnace.
13. DO NOT modify or alter the furnace cabinet in any way.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE
HAZARD
OF HIGH SURFACE
TEMPERATURE
AND
SHOULD
BE KEPT
AWAY
TO AVOID
BURNS
OR
CLOTHING IGNITION.
14. BE SURE factory
installed
grille is in place during
operation.
15. DO NOT connect this furnace to a chimney serving a
solid-fuel burning appliance.
1. USE ONLY
MANFACTURER'S
REPLACEMENT
PARTS. USE OF ANY OTHER PARTS COULD CAUSE
INJURY OR DEATH.
16. CLEAN the furnace and periodically inspect the pilot and
burner flame as described in the maintenance section of
this manual.
2. BE SURE furnace is for type of gas to be used. Check
the rating plate beneath the grille. Do not change it to
useothergases. Unsafe operation could resultandcould
cause bodily injury and death.
3. BE SURE the furnace is installed so that the drafthood is
located in the same atmospheric pressure zone as the
combustion air inlet to the furnace.
17. DISCONNECT
the furnace during supply line pressure
testing.
18. FOLLOWthe
lighting and operating procedures given in
this manual.
19. WARNING:
Any change to this furnace or its controls
could cause injury or death.
WARNING
/
DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER.
IMMEDIATELY
CALL A QUALIFIED
|
SERVICE TECHNICIAN TO INSPECT THE HEATER AND TO REPLACE ANY PART OF THE CONTROL SYSTEM
J
AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.
-4.