22. V.POSITION Gain Data
Function
The external control equipment changes the V. POSITION gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02
DATA00 : USER PICTURE Gain Flag
DATA01 : V.POSITION Gain Flag
DATA02 : V.POSITION Gain
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01
DATA00: USER PICTURE Gain Flag
DATA01: V.POSITION Gain Flag
PDP-614MX External Control Manual
03H
03H
01H
CKS
01H
C0H : -64
:
FFH : -01
00H : 0
01H : +01
:
40H : +64
CKS