19. TREBLE Gain Data
Function
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00
DATA00 : USER PICTURE Gain Flag
DATA01 : TREBLE Gain Flag
DATA02 : TREBLE Gain
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: TREBLE Gain Flag
20. BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00
DATA00 : USER PICTURE Gain Flag
DATA01 : BALANCE Gain Flag
DATA02 : BALANCE Gain
ACK
7FH 60H 80H 7FH 02H DATA00
DATA00: USER PICTURE Gain Flag
DATA01: BALANCE Gain Flag
1. SCREEN SIZE Select
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH 80H 60H 51H 01H DATA00
DATA00 02H : WIDE
03H : ZOOM
04H : STD
05H : FULL
06H : DOT BY DOT
08H : UNDERSCAN
09H : 14:9
PDP-614MX External Control Manual
DATA01
05H
05H
DATA01
05H
DATA01
05H
CKS
DATA02
CKS
04H
F3H : -13
:
FFH : -01
00H : 0
01H : +01
:
0DH : +13
04H
DATA02
CKS
02H
EAH : -22
:
FFH : -01
00H : 0
01H : +01
:
16H : +22
CKS