16. BLUE Gain Data
Function
The external control equipment changes the BLUE Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BLUE Gain Flag
DATA02 : BLUE Low
DATA03: BLUE High
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01
DATA00: USER PICTURE Gain Flag
DATA01: BLUE Gain Flag
PDP-614MX External Control Manual
01H
01H
03H
D8H :-40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H :-40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
CKS
03H
17