Fixed Glass Assembly; Install The Mesh; Install Trim And/Or Surround; Air Shutter Setting - Heat & Glo 6000GL-IPI-S Owner's Manual

Hide thumbs Also See for 6000GL-IPI-S:
Table of Contents

Advertisement

Figure 14.16 Front View
STEP 8. Log #6 (SRV2102-102):
of log #4 and log #5. Place the log so the long end of the "Y" rests on log #5 and the short end of the log rests on log #4.
The end of the log rests on the burner surface.
H. Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
• DO NOT strike, slam or scratch glass.
• DO NOT operate fi replace with glass removed, cracked,
broken or scratched.
• Replace as a complete assembly.
Removing Fixed Glass Assembly
• Pull the four glass assembly latches out of the groove on
the glass frame. Remove glass door from the appliance
(see Figure 14.18).
Replacing Fixed Glass Assembly
• Replace the glass door on the appliance. Pull out and
latch the four glass assembly latches into the groove on
the glass frame.
LATCHES
(BOTH BOTTOM
AND TOP)
GLASS
ASSEMBLY
Figure 14.18 Fixed Glass Assembly
I. Install the Mesh
Screen mesh is supplied with the optional doors.
56
6 6
Place log #6 on top of log #5 and log #4. There is a fl at spot molded into the top
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09
Figure 14. 17 Top View
J. Install Trim and/or Surround
• Install optional trim kits and/or surrounds using the
instructions included with the accessory.
• Use non-combustible materials to cover the gap between
the sheet rock and the appliance (when applicable to the
model).
K. Air Shutter Setting
Air shutter settings should be adjusted by a qualifi ed ser-
vice technician at the time of installation. The air shutter is
set at the factory for minimum vertical vent run. Adjust air
shutter for longer vertical runs. See Figure 14.19.
• Loosen the wing nut.
• Push the air handle in to close the air shutter.
• Pull the air handle out to open the air shutter.
• Tighten the wing nut.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Figure 14.19 Air Shutter
Air Shutter Settings
Burner
3/16 in.
Log
6 6
AIR SHUTTER
WING NUT
NG
LP
Open
3/8 in.
3/8 in.

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000gl-ipilp-s6000gl-ipilp-r6000gl-ipi-r