Download Print this page

Payne PG95XAT42060 Owner's Manual page 6

Condensing gas furnace

Advertisement

Fig.
6 - Do Not Light Burner
with Match
A92319
Read and follow the operating
instructions
on inside of
main furnace
door, especially
the item that reads as fol-
lows:
(See Fig. 31.)
"Wait 5 nfinutes
to clear out any gas. Then smell for gas,
including
near the floor. If you smell gas, STOP!
Fol-
low "B" in the safety information
on furnace label. If you
don't smell gas, go to the next step."
If a suspected
malfunction
occurs with your gas control
system, such as the burners
do not light when they
should,
refer to the shutdown
procedures
on inside of
main furnace
door, or in the "Shutting
Down Your Fur-
nace" section and call your dealer as soon as possible.
CHECK
AIR FILTER:
Before attempting to start your
furnace, be sure the furnace filter is clean and in place.
See "Perfornfing
Routine
Maintenance"
section in this
manual.
Do not run the furnace without
a filter in place.
Then proceed
as follows:
STEPS
FOR
STARTING
YOUR
FURNACE
1. Set your room thermostat to the lowest temperature setting
and set the "MODE" to "OFF.". See Fig. 7.
Fig. 7 - Lowest
Temperature
Setting
2. Close the external
manual
gas valve.
See Fig. 8.
A09564
i" I
'--"1
Fig. 8 - Close Valve
3. Turn OFF electrical
supply to the furnace.
See Fig. 9.
Fig. 9 - Turn
Off Electrical
Supply
4. Remove
the main furnace
door.
See Fig. 10.
A06188
A92185
Al1302
Fig. 10 - Remove
Main
Furnace
Door
(Upflow
Configuration)
5. Turn the control switch on the gas control to the OFF position
and wait five nfinutes. See Fig. 10. Then smell for gas, includ-
ing near the floor. If you smell gas, STOP! Follow "B" on fur-
nace label. If you don't smell gas, go to next step.