Advertisement

Product Data
The model PG92SCS is an efficient and robust 4- -way multipoise
condensing furnace with features including single- -stage heating
and a rugged PSC Blower Motor. The PG92SCS builds on the
many Payne successes in the furnace industry and establishes a
new standard for all high- -efficiency gas furnaces.
S Heating efficiency of 92.1% AFUE.
S Direct- -vent/sealed combustion, single- -pipe venting or
ventilated combustion air.
S PSC blower motor.
S 4- -way multipoise furnace.
S Hot surface ignition.
S LED diagnostics and self test feature.
S Stores fault codes during power outages.
S Adjustable heating air temperature rise.
S Adjustable cooling airflow.
S Approved for Manufactured Housing/Mobile Home applications
with MH accessory kit.
S Approved for Twinning applications (48060 through 60120
sizes, only).
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1-inch water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
A11300
Use of the AHRI Certified
Mark indicates a
TM
manufacturer's participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
1
PG92SBS 048080 ONLY
CONDENSING GAS FURNACE
STANDARD FEATURES
CERTIFIED
PG92SCS ALL
SERIES A

Advertisement

Table of Contents
loading

Summary of Contents for Payne PG92SCS

  • Page 1 CONDENSING GAS FURNACE SERIES A Product Data The model PG92SCS is an efficient and robust 4- -way multipoise condensing furnace with features including single- -stage heating and a rugged PSC Blower Motor. The PG92SCS builds on the many Payne successes in the furnace industry and establishes a new standard for all high- -efficiency gas furnaces.
  • Page 2: Dimensions

    The heat pump also delivers high-efficiency cooling in the summer. operation. By sealing the entire combustion vestibule, the entire Robust Igniter — Payne’s unique SiN igniter is not only furnace can be made quieter, not just the burners. physically robust but it is also electrically robust. It is capable of Monoport Burners —...
  • Page 3: Specifications

    SPECIFICATIONS The furnace should be sized to provide 100 percent of the design method to calculate heating load estimates and select the furnace. heating load requirement plus any margin that occurs because of Excessive oversizing of the furnace may cause the furnace and/or furnace model size capacity increments.
  • Page 4: Furnace Components

    MODEL NUMBER NOMENCLATURE Example of a Model Number 3 - 4 8 - 9 10 - 12 15 - 16 Brand Base Effy. Product Voltage/Motor Major Series Htg. Stages Cooling Cap. Minor Series Heating Cap. Width/Variation Variations Brand 0 - +90 AFUE 2 - +92 AFUE Product 3 - +93 AFUE...
  • Page 5 ACCESSORIES DESCRIPTION PART NUMBER 30040 48060 48080 60080 48100 60100 60120 Venting Accessories Vent Kit - Through the Cabinet KGADC0101BVC Vent Terminal - Concentric - 2” (51 mm) KGAVT0701CVT Vent Terminal - Concentric - 3” (76 mm) KGAVT0801CVT See Venting Tables Vent Terminal Bracket - 2”...
  • Page 6 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) Test Airflow Delivery @ Various External Static Pressures Return Air Wire Lead Cooling CFM / Furnace Connection Color Tons Black 388 1145 1100 1060 1015 Blue 030040 SIDE/BOTTOM Yellow Black 376 1600 1545 1505 1475 1505 1445 1400 1330 1235 1140 Yellow 377 1380 1340 1335 1330 1320 1285 1225 1155 1085 1000 048060...
  • Page 7 MAXIMUM ALLOWABLE EXPOSED VENT LENGHT INSULATION TABLE Table 1 – Maximum Allowable Exposed Vent Length in Unconditioned Space - - Ft. Unit Size 40,000* BTUH 60,000 BTUH Uninsulated 3/8-in. Insulation 1/2-in. Insulation Uninsulated 3/8-in. Insulation 1/2-in. Insulation Pipe Dia. 1 ½ 2 ½...
  • Page 8: Maximum Equivalent Vent Length

    MAXIMUM EQUIVALENT VENT LENGTH Table 2 – Maximum Equivalent Vent Length - - Ft. NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 3 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application. 40,000 Outlet choke Unit Size...
  • Page 9: Venting System Length Calculations

    Venting System Length Calculations The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent length of elbows used in the venting system from Table 3. Standard vent terminations or factory accessory concentric vent terminations count for zero deduction. See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems.
  • Page 10: Return Air Temperature

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 11 RESTRICTIONS IN HORIZONTAL CONFIGURATIONS HORIZONTAL LEFT TOP RETURN NOT PERMITTED FOR ANY MODEL. SEE TABLE BELOW. SUPPLY RETURN *RETURN *HORIZONTAL LEFT BOTTOM RETURN NOT PERMITTED FOR ALL MODELS. SEE TABLE BELOW. A14006 CASING HORIZONTAL LEFT RETURN AIR CONNECTIONS INPUT* WIDTH CONNECTION AT CONNECTION AT CONNECTION AT...
  • Page 12 Payne cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 13: Typical Wiring Schematic

    TYPICAL WIRING SCHEMATIC FIELD 24-VOLT WIRING FIELD 115-, 208/230-, 460-VOLT WIRING FACTORY 24-VOLT WIRING FACTORY 115-VOLT WIRING NOTE 2 1-STAGE THERMOSTAT FIVE FIELD-SUPPLIED TERMINALS WIRE FUSED DISCONNECT BLOWER THREE-WIRE DOOR 208/230- OR HEATING- SWITCH 460-VOLT ONLY THREE PHASE 208/230- W/W1 VOLT NOTE 1 SINGLE...
  • Page 14: Dimensional Drawing

    DIMENSIONAL DRAWING A12267 PG92SCS SHIP WT. LB (KG) FURNACE SIZE CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE 30040 14--- 3/16 (361) 12--- 1/2 (319) 12--- 9/16 (322) 7--- 1/8 (181) 121.0 (55.0) 48060 142.0 (64.5) 17--- 1/2 (445)
  • Page 15: Guide Specifications

    GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane).
  • Page 16 Catalog No: SS---PG92SCS---03 E2014 Payne Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 12/14 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: SS--- PG92SCS--- 02...

Table of Contents