Performance
Data Sheet
SmartWater
Filtration
System
GSWF Cartridge
This system has been tested according
to NSF/ANS142/53
for reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the permissible
limit for water leaving
the system,
as specified
in NSF/ANS142/53.
*
_7 0 0% safety f_ctors built in for unmetered
usage)
Parameter
USEPA
Influent
% Rec uction
Min. Required
MCL
Average
Average
Minimum
Reduction
Chlorine
--
1.845 mg/L
> 97.29%
96.43%
_>50%
T&O
.....
Particulate**
--
143,333 #/mL
99.98%
99.91%
_>85%
2: Aesthetic Effects
Efflu ;nt
Average
Maximum
< 0.05 mg/L
0.05 mg/L
29.83#/mL
140#/mL
Standard No.
[nfluent
Challenge
Concentration
2.0 mg/L+l
0%
at least. 10,000 part.ides/rot
Standard
Influent Challenge
Concentration
1+1NTU *_*
Minimum 50,000 L
0.15 mg/L_+lO%
0.15 mg/L_+lO%
0.002mg/L+l0%
0.009
mg/L+_l
0%
o. 53: Health
Effects
Parameter
USEPA
Influent
Efflu_ _nt
% RedL :tion
Min. Required
MCL
Average
Average
Maximum
Average
Minimum
Reduction
Turbidity
1 NTU***
10.3 NTU***
0.106 NTU
0.14 NTU
98.97%
98.61%
0.5 NTU
Cysts
99.95% Reduction
200,000 #/L
0
0
> 99.99%
> 99.99%
> 99.95%
Lead at pH 6.5
0.015 mg/L
0.15 mg/L
< 0.001 mg/L
< 0.001 mg/L
> 99.33%
> 99.33%
0.010 mg/L
Lead at pH 8.5
0.015 mg/L
0.14 mg/L
0.001 mg/L
0.003 mg/L
> 99.29%
97.86%
0.010 mg/L
Lindane
0.0002 mg/L
0.0216 mg/L
< 0.00002 mg/L
< 0.00002 mg/L
99.07%
98.75%
0.0002 mg/L
Atrazine
0.003 mg/L
0.008 mg/L
< 0.002 mg/L
< 0.002 mg/L
> 76.12%
> 66.67%
0.003 mg/L
Tested using a flow rate of L_ 5 gpm; pressure
of 60 psLq; p H of Z 5 + O,5; temp, of 68 _" + 5_F (20 _" + 3 _'C)
* * Measurement
in P_lrticles/ml,
P_lrticles used were O,5- 7 microns
* * * N TU Nephelometric
Turbidity units
Opera ting Specifica
tions
[] Capacity: certified for up to 750 gallons (2,838I);up to six months
[] Pressure requirement: 40-120 psi (2,8-8,2 bar)
[] Temperature: 33-100°F (0,6-38°C)
[] Flow Fate: 0,5 gpm (1,9 Ipm)
General
Instaflation/Operation/Maintenance
Requirements
[] Flush new cartridge
at full flow for 3 minutes to purge out trapped
air,
[] Replace cartridge
when flow becomes too slow,
Special
Notices
[] Installation
instructions,
parts and service availability,
and standard
warranty
are included with the product when shipped,
[] This drinking water system must be maintained
according
to manufacturer's
instructions,
including
replacement
of filter
cartridges,
[] Do not use with water that is microbiologically
unsafe or of unknown
quality without
adequate
disinfection
before or after
the system, Systems certified
for cyst reduction
may be used on disinfected
water that may contain filterable
cysts,
[] The contaminants
or other substances
removed or reduced by this water treatment
system are not necessarily
in your water,
[] Check for compliance
with the state and local laws and regulations,
[] Note that while the testing was performed
under standard
laboratory
conditions,
actual
performance
may vary, Systems
must be installed and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines,
System
tested
and certified
by NSF International
against
Standard
42 for the reduction
of
chlorine,
taste and odor, particulate
Class I and Standard
53 for the reduction
of cyst,
lead,
Lindane, Atrazine
and turbidity,
Manufactured
for: General
Electric
Company,
Louisville,
KY 40225
]