La Crosse Technology WS-9620U-IT Manual
La Crosse Technology WS-9620U-IT Manual

La Crosse Technology WS-9620U-IT Manual

Wireless weather station

Advertisement

Contents
Language
______________________________________________________________________
English
French
Spanish
1
Page
1
74

Advertisement

Table of Contents
loading

Summary of Contents for La Crosse Technology WS-9620U-IT

  • Page 1 Contents Language Page ______________________________________________________________________ English French Spanish...
  • Page 2 TABLE OF CONTENTS Topic Page Inventory of Contents Features Setting Up Battery Installation Function keys LCD Screen and Settings WWVB Radio Controlled Time Manual Settings Weather Forecast and Tendency Display of Indoor Temperature and Humidity Reading Display of Outdoor Temperature and Humidity Reading Display of Indoor Minimum / Maximum records Display of Outdoor Minimum / Maximum records 915 MHz Reception...
  • Page 3: Inventory Of Contents

    INSTANT TRANSMISSION is the state-of-the-art This product offers: new wireless transmission technology, exclusively designed and developed by LA CROSSE TECHNOLOGY. INSTANT TRANSMISSION offers you an immediate update (every 16 seconds!) of all your outdoor data measured from the sensors: follow your climatic variations in real-time! INVENTORY OF CONTENTS Wireless Weather Station...
  • Page 4 • WWVB Radio controlled time with manual setting options • Time reception ON/OFF • 12/24 hour time display • Hour and minute display • Time zone option ±12 hours • Wireless transmission at 915 MHz • Signal reception intervals of 16-seconds •...
  • Page 5 happen after 15 minutes, the batteries will need to be removed from both units and reset from step 1. In order to ensure sufficient 915 MHz transmission there should be a distance of no more than 330 feet (100 meters) between the final position of the Weather Station and the sensor (see notes on “Mounting”...
  • Page 6 Note: After the three sensors have been set up, user may need to check the readings displayed on the Weather Station against those being shown on the sensor displays, in order to recognize which channel each sensor is displayed. If the signal reception is not successful on the first frequency (915MHz) for 45 seconds, the frequency is changed to 920MHz and the learning is tried for another 45 seconds.
  • Page 7 The Outdoor Thermo-hygro Sensor • Remote transmission of outdoor temperature and humidity to Weather Station by 915 MHz • LCD alternates between temperature and humidity readings. • Water-resistant casing • Wall mounting case • Mount in a sheltered location. Avoid direct rain and sunlight BATTERY INSTALLATION INSTALL AND REPLACE BATTERIES IN THE WEATHER STATION...
  • Page 8: Battery Change

    Note: In the event of changing batteries in any of the units, all units need to be reset by following the setting up procedures. This is because a random security code is assigned by the sensor at start-up and this code must be received and stored by the Weather Station in the first 3 minutes of power being supplied to it BATTERY CHANGE: It is recommended to replace the batteries in all units on an annual basis to ensure...
  • Page 9: Lcd Screen And Settings

    • Press to reset the minimum or maximum temperature and humidity records of the indoor or the currently selected outdoor channel (will reset all records to current level) MIN/ MAX • To toggle between the minimum/maximum outdoor temperature and minimum/ maximum indoor temperature and humidity data Note: The time/date shown is corresponding to MIN/MAX temperature data.
  • Page 10: Weather Forecast

    *When the outdoor signal is successfully received by the Weather Station, this icon will be switched on. (If not successful, the icon will not be shown in LCD) The user can easily see whether the last reception was successful (icon on) or not (icon off). On the other hand, the short blinking of the icon shows that a reception is currently taking place.
  • Page 11: Manual Settings

    continuously throughout the United States at 60 kHz. The signal can be received up to 2,000 miles away through the internal antenna in the Wireless Weather Station. However, due to the nature of the Earth’s Ionosphere, reception is very limited during daylight hours. The wireless weather station will search for a signal every night when reception is best.
  • Page 12: Lcd Contrast Setting

    LCD CONTRAST SETTING flashing The LCD contrast can be set to 8 different levels to suit the user’s needs (default LCD contrast setting is LCD 4). To set the desired contrast level: The above display will be seen. Press the + key to select the level of contrast desired.
  • Page 13: Time Reception On/Off Setting

    The digit “DST ON” will start flashing on the LCD. Use the + key to turn On or OFF the daylight saving time function. Confirm with the SET key and enter the “Time reception On/Off setting” or exit the setting mode by pressing the CH key. TIME RECEPTION ON/OFF SETTING Flashing (time reception icon)
  • Page 14: 12/24 Hour Time Display Setting

    12/24 HOUR TIME DISPLAY SETTING flashing After setting time reception ON/OFF, press the SET key, “12h” or “24h” flashes in the LCD. (default 12 h) Press the + key to select the “12h” or “24h” display mode. Press the SET again to confirm and to enter the “Manual Time setting” or exit the setting mode by pressing the CH key.
  • Page 15: Calendar Setting

    CALENDAR SETTING Year "Date. Month." (for 24h time display) "Month. Date." (for 12h time display) The date default of the Weather Station is January 1 , 2006 (01.01.06), after initial set- up. The date is only used for recording of MIN/MAX values and only show during set- up.
  • Page 16: F/°C Temperature Unit Setting

    °F/°C TEMPERATURE UNIT SETTING flashing The default temperature reading is set to °F (degree Fahrenheit). To select °C (degree Celsius): The “°F/ °C” will be flashing, use the + key to toggle between “°F” and “°C”. Once the desired temperature unit has been chosen, confirm with the SET key and enter the “Weather Forecast Icon Sensitivity setting”...
  • Page 17: Weather Forecast And Tendency

    WEATHER FORECAST AND TENDENCY: The weather forecast icons (Oscar Outlook): One of the 15 different weather icons (featuring Oscar Outlook with different clothing suggestions) is displayed in the centre of LCD, which indicates the different forecast weather condition due to air pressure level (Sunny, Sunny + Cloudy or Cloudy + Rainy) and the current outdoor temperature (Temperature value detected by Channel 1): ≥...
  • Page 18 ≥ 78.8°F 50-66°F 32 – 49.8°F < 32°F (0°C) 66.2 – 8.6°F (10 – 8.9°C) (0 – 9.9°C) (26°C) (19 –25.9°C) Cloudy + Rainy Note: After setting up, readings for weather forecasts should be disregarded for the next 48- 60 hours. This will allow sufficient time for the Weather Station to collect air pressure data at a constant altitude and therefore result in a more accurate forecast.
  • Page 19: The Weather Tendency Indicator

    THE WEATHER TENDENCY INDICATOR Working together with the weather icons are the weather tendency indicators (the upward and downward arrows located near Oscar Outlook). When the indicator points upwards, the air-pressure is increasing and the weather is expected to improve, but when indicator points downwards, the air-pressure is dropping and the weather is expected to become worse.
  • Page 20: Display Of Outdoor Temperature And Humidity Reading

    DISPLAY OF OUTDOOR TEMPERATURE AND HUMIDITY READING: Sensor identification No. (shown when more than one sensor is used) Outdoor Humidity Outdoor Temperature in °F The last LCD section shows the outdoor temperature and a channel number under the temperature will also show if more than one sensor has been used. DISPLAY OF INDOOR MINIMUM AND MAXIMUM RECORDS: In normal display mode, press the MIN/ MAX button five times.
  • Page 21 Press the MIN/ MAX button once more to display the date of recording of this temperature reading. Then press the MIN/MAX button one more time, the minimum indoor temperature and humidity will be shown in the bottom section of LCD. Also the time of recording this temperature will be displayed By pressing the MIN/MAX button one more time, the date of recording this temperature will be shown.
  • Page 22 Time of Recording the Minimum Temperature Minimum Humidity Minimum Temperature Minimum Icon By pressing the MIN/MAX button one more time, the date of recording this temperature will be shown. Press one more time the MIN/ MAX button to advance to the indoor MIN/ MAX display RESETTING THE OUTDOOR MINIMUM /MAXIMUM RECORDS Note:...
  • Page 23 Press the MIN/ MAX button once. The "max" icon will be displayed. Press the SET button; this will reset the outdoor maximum temperature and humidity record to the current value. Press MIN/ MAX button twice more to show the minimum data. The "min" icon will be displayed.
  • Page 24 MOUNTING POSITIONING THE WEATHER STATION: The Weather Station has been designed to be hung onto a wall or free standing. To wall mount Choose a sheltered place. Avoid direct rain and sunshine. Before wall mounting, please check that the outdoor temperature and humidity values can be received from the desired locations.
  • Page 25: Care And Maintenance

    To wall mount: 1. Secure the bracket onto a desired wall using the screws and plastic anchors. 2. Clip the remote thermo-hygro sensor onto the bracket. Note: Before permanently fixing the sensor wall base, place all units in the desired locations to check that the outdoor temperature reading is receivable.
  • Page 26: Specifications

    SPECIFICATIONS: Temperature measuring range: Indoor 14.1°F to +139.8°F with 0.2°F resolution (-9.9ºC to +59.9ºC with 0.1ºC resolution, “OF.L” displayed if outside this range) Outdoor -39.8°F to +139.8°F with 0.2°F resolution (-39.9ºC to +59.9ºC with 0.1ºC resolution, “OF.L” displayed if outside this range) Relative humidity measuring range: 1% to 99% with 1% resolution (displays “- -”...
  • Page 27 La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center. La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or reconditioned parts or products if found to be defective during the limited warranty period specified above.
  • Page 28 LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION.
  • Page 29 All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical or chemical procedures without written permission of the publisher. This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked and corrections made in the next issue.

This manual is also suitable for:

Ws-9620u-it-jcbp

Table of Contents