Installation - Salus SP120 Instruction Manual

S-series single channel controller
Table of Contents

Advertisement

SP120 Manual Ver 005.qxd:Layout 1

INSTALLATION

Please read the important safety information at the start of this manual before you begin to install
the device. The ideal position to locate the SP120 programmable heating controller is about 1.5m
above floor level. It should be mounted in a location where the controller is easily accessible,
reasonably lit and free from extremes of temperature and draughts. Do not mount the controller on
an outside wall, above a radiator or in a location where it may be subjected to direct sunlight.
The SP120 should be mounted in a location where it will not come into contact with moisture or
condensation, as this can affect the Touch Ring operation.
To ensure trouble free reception for both the Radio Controlled Clock (RCC) and the Radio Frequency
(RF) signal, always ensure that the programmable controller is mounted away from any possible
sources of interference (such as radios, TV sets, computers, etc.), and is not mounted on or in close
proximity to large metal objects. Installing the SP120 in enclosed areas such as cellars and basements
is not recommended.
The electrical connections to the SP120 are made to the terminal strip within the controller itself.
Connection details are shown below - no Earth connection is required for the correct and safe
operation of the SP120.
Volt Free Connections
Terminal Description
4 (COM)
Volt Free Common
3 (NO)
Normally Open
2 (NC)
Normally Closed
1
No connection
L
Mains Live
N
Mains Neutral
4
6/1/11
09:00
230V AC Connections
Terminals
Terminal
4
3 (SL on)
2 (SL off)
1
L
N
Page 4
Description
Linked to Live
Switched Live On
Switched Live Off
Live
Mains Live
Mains Neutral
SP120 INSTRUCTION MANUAL
Terminals

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents