Ken A Vision Comprehensive Scope 2 T-19011C Instruction Manual

Ken A Vision Comprehensive Scope 2 T-19011C Instruction Manual

Monocular/dual viewing/binocular/trinocular
Hide thumbs Also See for Comprehensive Scope 2 T-19011C:

Advertisement

Comprehensive Scope 2
Instruction Manual
T-19011C - Monocular
T-19021C - Dual Viewing
T-19031C - Binocular
T-19041C - Trinocular

Advertisement

loading

Summary of Contents for Ken A Vision Comprehensive Scope 2 T-19011C

  • Page 1 Comprehensive Scope 2 Instruction Manual T-19011C - Monocular T-19021C - Dual Viewing T-19031C - Binocular T-19041C - Trinocular...
  • Page 2: Specifications

    Application Thank you for purchasing the new Ken-A-Vision Comprehensive Scope 2 microscope. You will be pleased to find that this is a finely built, high quality, versatile unit that should work well within your curriculum. Comprehensive Scope 2 base is modularly designed and while maintaining a common, standard base unit it is possible to make changes in accessories.
  • Page 3 Ken-A-Vision Product # T-19011C T-19021C T-19031C T-19041C 4 holed, 45° reversed nosepiece; 360° 4x DIN Plan Achromat N.A. 0.10 Objective lens 10x DIN Plan Achromat N.A. 0.25 Objective lens 40x DIN Plan Achromat N.A. 0.65 Objective lens, Spring Loaded 100x DIN Plan Achromat N.A.
  • Page 4 Ken-A-Vision Product # T-19011C T-19021C T-19031C T-19041C Detachable Low Voltage External Power Supply Input -110v-240v, ±500mA; Output 5.5v, ±500mA Standard Stage -Spring loaded stage clips; Con- denser built-in (0.65 N.A.); 5 hole Disc Dia- phragm Mechanical Stage - Coated 130mm x 120 mm;...
  • Page 5: Normal Operation

    becomes fully depressed into the socket, the stop needs to be adjusted, by loosening the locking nut and knurled knob and re-setting the stop position. NORMAL OPERATION General Operation Notes Eyepieces The widefield eyepiece is locked in to place to avoid loss of eyepiece. There is a pointer built-in to (only one if head has two eyepieces) the eyepiece to help identify parts of observed specimens.
  • Page 6 T-19031C The binocular eyepiece has a diopter on both eye tubes for focusing. The Interpupiliary Adjustment. When using the binocular microscope there is an adjustment for the distance between the viewer's eyes called interpupilliary adjustment. The eyepiece lenses will spread apart or get closer together to fit each individual.
  • Page 7 Abbé Condenser 1.25 N.A. (included on models T-19031C & T-19041C) The purpose of the condenser lens is to focus the light onto the specimen. (adjust the amount of light needed on a specimen) The N.A. of 1.25 gives an Abbé condenser the ability to be used with higher magnification 100x objective lens.
  • Page 8: Care And Maintenance

    CARE AND MAINTENANCE Your microscope is a fine precision instrument and should be treated with care. When not in use it should be protected from dust by the plastic cover provided. Lenses and eyepieces should be cleaned periodically with optical lens tissue which is soft and lint free.