HP FTAM/9000 Reference Manual page 77

Table of Contents

Advertisement

MESSAGE
4002
CAUSE
ACTION
MESSAGE
5002
CAUSE
ACTION
Chapter 3
F_ATTRIB_CANNOT_CHNG
You cannot change the attribute for one of the
following reasons.
• When you selected the file, you did not set
requested_access to include
FT_FA_CHANGE_ATTRIBUTE.
• You tried to add a duplicate access control
element for an existing initiator identity.
• You tried to change a file's name to the name of a
file that already exists.
Use the appropriate corrective action, as follows.
• Deselect the file and select it again with
requested_access set to include
FT_FA_CHANGE_ATTRIBUTE.
• Remove the access control element for the
existing initiator identity and insert one for the
initiator identity you want.
• Change the name of the file to one that does not
exist.
F_BAD_FADU_TYPE_ERR
The structure_id describing the type of FADU
information is not correct.
Set the structure_id to a valid value. Use
FT_DATA_UNIT for all document types and
FT_NODE_DESC for FTAM-2 document types only.