Function
Dig Out13 NO/NC (Param244)
Dig Out14 NO/NC (Param245)
Dig Out15 NO/NC (Param246)
AlarmReray NO/NC (Param247)
OLAlarmSignalSel (Param248)
OL Alarm Level 1 (Param249)
ArrivalFreq Acc1 (Param250)
ArrivalFreq Dec1(Param251)
PID DeviationLvl (Param252)
ArrivalFreq Acc2 (Param253)
ArrivalFreq Dec2 (Param254)
OV-TRQ FW-V (Param255)
OV-TRQ RV-R (Param256)
OV-TRQ RV-V (Param257)
OV-TRQ FW-R (Param258)
Thermal Warn Lvl (Param259)
AlarmMode Select (Param260)
ZERO Speed Level (Param261)
Data Command Sel (Param262)
CommSpeed Select (Param263)
Comm ID Select (Param264)
CommBitLengthSel (Param265)
CommParitySelect (Param266)
Comm StopBit Sel (Param267)
Comm Wait Time (Param268)
O Adjustment (Param269)
OI Adjustment (Param270)
O2 Adjustment (Param271)
Therm-Adjustment (Param272)
AM Offset Adjust (Param273)
AMI Adjustment (Param274)
AMI OffsetAdjust (Param275)
Support service
Service name
Get_Attribute_Single
Set_Attribute_Single
(6) Extend Group C object Class ID=106
Function
UP/DWN Selection (Param276)
Reset Selection (Param277)
Reset f MacthSel (Param278)
OL Alarm Level 2 (Param279)
O ZeroAdjustment (Param280)
OIZeroAdjustment (Param281)
O2ZeroAdjustment (Param282)
Support service
Service name
Get_Attribute_Single
Set_Attribute_Single
Inst
Attr
Size
1
133
1
1
134
1
1
135
1
1
136
1
1
140
1
1
141
2
0 to 200(%) (constant current)
1
142
4
1
143
4
1
144
2
1
145
4
1
146
4
1
155
1
1
156
1
1
157
1
1
158
1
1
161
2
1
162
1
1
163
2
1
170
1
1
171
1
1
172
1
1
173
1
00(No Parity)/01(Even Parity)/
1
174
1
1
175
1
1
178
2
1
181
2
1
182
2
1
183
2
1
185
2
1
186
1
1
187
1
1
188
1
Code
H'0E
H'10
Inst
Attr
Size
1
101
1
1
102
1
1
103
1
00(0Hz start)/01(Synchronize)
1
111
2
0 to 200(%) (constant current)
1
121
2
1
122
2
1
123
2
Code
H'0E
H'10
31
APPENDIX PARAMETER OBJECT LISTS
Monitoring/Setting Range
00(NO)/01(NC)
00(NO)/01(NC)
00(NO)/01(NC)
00(NO)/01(NC)
00(Valid)/01(Valid at const)
0.00 to 400.00(Hz)
0.00 to 400.00(Hz)
0.0 to 100.0(%)
0.00 to 400.00(Hz)
0.00 to 400.00(Hz)
0 to 200(%) (~55KW)
0 to 180(%) (75~132KW)
0 to 200(%) (~55KW)
0 to 180(%) (75~132KW)
0 to 200(%) (~55KW)
0 to 180(%) (75~132KW)
0 to 200(%) (~55KW)
0 to 180(%) (75~132KW)
0 to 100(%)
00(Invalid)/01(3bit)/02(4bit)
0.00 to 100.00(Hz)
02(Operator)/03(RS485)/
04(Option 1)/05(Option 2)
02(loop back)/
03(2400bps)/04(4800bps)/
05(9600bps)/06(19200bps)
1 to 32
7(7bit)/8(8bit)
02(Odd Parity)
1(1bit)/2(2bit)
0 to 1000(ms)
0 to 65530
0 to 65530
0 to 65530
0.0 to 1000.0
0.0 to 10.0(V)
0 to 255(%)
0.0 to 20.0(mA)
Monitoring/Setting Range
00(Not keep)/01(Keep)
00(Reset at close)/
01(Reset at open)/
02(Only trip clear)
0 to 65530
0 to 65530
0 to 65530
Magnifi-
Access
Com
cation
rule
mand
1
Get/Set
C033
1
Get/Set
C034
1
Get/Set
C035
1
Get/Set
C036
1
Get/Set
C040
1
Get/Set
C041
100
Get/Set
C042
100
Get/Set
C043
10
Get/Set
C044
100
Get/Set
C045
100
Get/Set
C046
1
Get/Set
C055
1
Get/Set
C056
1
Get/Set
C057
1
Get/Set
C058
1
Get/Set
C061
1
Get/Set
C062
100
Get/Set
C063
1
Get/Set
C070
1
Get/Set
C071
1
Get/Set
C072
1
Get/Set
C073
1
Get/Set
C074
1
Get/Set
C075
1
Get/Set
C078
1
Get/Set
C081
1
Get/Set
C082
1
Get/Set
C083
10
Get/Set
C085
10
Get/Set
C086
1
Get/Set
C087
10
Get/Set
C088
Magnifi-
Access
Com-
cation
rule
mand
1
Get/Set
C101
1
Get/Set
C102
1
Get/Set
C103
1
Get/Set
C111
1
Get/Set
C121
1
Get/Set
C122
1
Get/Set
C123