Thermostat
Installation
(ton't)
NOTE
MV "--X.-_J_
-LONGER
.---,.- 1.0 .-'--
CYCLE
HEAT AN 0,P TOR
SETTING
'_
u_.-_,._m
Refer to installation instructions packed in the thermostat
carton if you have any doubt about the above procedures.
When all is adjusted properly, the furnace burner should
shut off slightly before the desired room temperature is
reached. The stored heat in the appliance is enough to
bring room temperature up to desired level. The heat
anticipator thus makes it possible to maintain very close
temperature control.
For longer "ON"
time, move anticipator clockwise.
For shorter "ON" time, move anticipator counterclockwise.
SIDE OUTLET NO. 6701
Optional
Accessory
Installation
CUT WALL OPENING(S)
REAR OUTLET NO. 6801
SHORT REAR OUTLET NO. 6802
Make an opening(s) in the wall(s) for a Side and/or a Rear
Outlet Register. See Fig. 27.
CAUTION
Use only Boots and Grilles
provided
by the
manufacturer.
CLEARANCES
IMPORTANT
Carefully follow all measurements
and clearances given
to ensure proper installation.
When SiDE OUTLET 6701 is used, the furnace casing
must be exactly 4 inches from an adjacent
side wall
(except
may be 3/4" minimum
when
1-WAY FRONT
DIFFUSING
GRILLE is used). See Figs. 28 and 29,
page 22.
When REAR OUTLET 6801 or SHORT REAR OUTLET
6802 are used, the furnace casing must be a minimum
of 12 inches from an adjacent side wall. See Figs. 3D and
3F, page 7.
CUT CASING OPENING(S)
Before setting the furnace into position, cut a 5 x 7 inch
rectangular opening for Side Register, or 7 x 11 inch open-
ing for a Rear Outlet Register where marked on the fur-
nace casing. Cut carefully as edges must be straight and
smooth. See Fig. 13, page 12.
CUT WALL OPENING
SIDE OUTLET
REAR OUTLET
FURNACE "BACK"
AGAINST WALL
_
a-1/4" L_
ll-s/8"
F1NI_tlE9FLOOR ,-J_
II
. II
°IIs'_os/ II
Ill
I IR,-v,-
.-s/s'! I
II
l
II
11
RNISHED FL_
/1/1
m '"
3/4"
MIN
WHEN
OPTIONAl,
"J_
-
6704 ONE-WAY
3/4"
FRONT
DIFFUSING
GRILLE
IS USED
--21--

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents