Gas Supply Requirements - Whirlpool WGD9400SW1 Use & Care Manual

Electronic gas dryer
Hide thumbs Also See for WGD9400SW1:
Table of Contents

Advertisement

Available languages

Available languages

Must include a shutoff valve:
In the U.S.A.:
An individual manual shutoff valve must be installed within
six (6) feet (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1. The location should be easy to
reach for opening and closing.
In Canada:
An individual manual shutoff valve must be installed in
accordance
with the B149.1, Natural Gas and Propane
Installation Code. It is recommended
that an individual
manual shutoff valve be installed within six (6) feet (1.8 m)
of the dryer.
The location should be easy to reach for opening and closing.
A
C
E
B
D
A. %" flexible gas connector
B. %" pipe to flare adapter fitting
C. Vs" NPT minimum plugged tapping
D. Y," NPT gas supply line
E. Gas shutoff valve
Gas supply connection requirements
Use an elbow and a 3/8"flare x 3/8"NPT adapter fitting
between the flexible gas connector and the dryer gas pipe, as
needed to avoid kinking.
Use only pipe-joint
compound.
Do not use TEFLON °t tape.
This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard
for connectors
for gas appliances, ANSI Z21.24 or CSA 6.10.
Burner input requirements
Elevations
above 10,000 ft (3,048 m}:
When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner Btu rating shown on the model/serial number plate
is required for each 1,000 ft (305 m) increase in elevation.
Gas supply pressure testing
The dryer must be disconnected
from the gas supply piping
system during pressure testing at pressures greater than
1/2psi.
Dryer gas pipe
The gas pipe that comes out through the rear of your dryer
has a %" male pipe thread.
A. Y2"NPT gas supply line
B. _" NPT dryer pipe
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height
must be an additional 10" (25.4 cm) or 15.5" (39.4 cm) from the
floor, depending
on the pedestal model, For a garage
installation, the gas pipe height must be an additional
18" (46 cm) from the floor.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow
these instructions can result in death
or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected
into any gas vent,
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wgd9400su1Wgd9300vu0Wgd9400st1Wgd9200sq1Wgd9400sb1

Table of Contents