Trane YC-UC-4 User's Information Manual page 5

Combination cooling/gas heating packaged unit

Advertisement

User's Information
Regular
Dealer
Maintenance
ELECTRIC SHOCK HAZARD. To prevent injury or death due
to electrical shock or contact with moving parts. Lock unit
disconnect switch in open position before servicing unit.
Cooling Season
To keep your unit operating
safely and efficiently,
a qualified
service technician
should check the entire system
seasonally,
and any other time that you feel a check is needed. Your
service technician
may examine
these areas of the unit:
1. filters
(for possible
cleaning)
2. motors
(condenser
and evaporator
motors are perma-
nently lubricated)
3. gaskets
(for possible replacement)
4. refrigerant
coils (for possible
cleaning)
5. safety
controls
(for mechanical
cleaning)
6. electrical
components
and
wiring
(for possible replace-
ment and connection
tightness)
7. condensate
drain
(for possible cleaning)
8. inspect
the unit duet connections
to see that they are
physically
sound and sealed to the unit casing.
9. inspect
the unit mounting
support
to see that it is sound.
10.inspect
the unit to see that there is no obvious unit
deterioration.
Heating
Season
At the beginning
of each heating
season complete
the unit
inspections
and service routines
described
in this section.
These steps should be performed
ONLY by a qualified
service
technician.
1. Inspect the control panel wiring and heating
controls to
make sure connections
are tight and wiring insulation
is
intact.
2. Cheek the operation
of the gas ignition
system.
a. Turn the unit on and off at the thermostat
to be sure
the ignition
control and spark electrode
are operating.
b. Turn off the gas supply with the unit operating
to
verify that the gas valve closes and that a re-ignition
cycle is initiated
by the ignition control.
3. Check the burner
manifold
pressure.
A pressure
tap is
provided
in the gas valve for this purpose.
4. Visually
inspect all of the unit's flue product
passageways
for excessive deposit buildup
or corrosion.
If buildup
or
corrosion
is apparent,
perform the necessary
repairs.
5. Arrange
for a qualified
service technician
to inspect the
unit every heating
season to maintain
safe and efficient
operation.
6. Visually check the main burner
flames.
They should be
bright blue flames extending
up to the heat exchanger
sections.
GAS VALVE
\\
MANUAL
\\
ON/OFF
__
SWITCH
MANIFOLD
ORIFICE
BURNER
GAS VALVE
MANUAL
ON/OFF
SWITCH
R
M
= k ._/
::
k
Figure 2. Gas Valve with On/Off "Toggle" Switch
ELECTRIC SHOCK HAZARD. Should overheating occur, or
the gas supply fail to shut off, shut off the manual gas
valve to the furnace before shutting off the electrical
supply.
In the event that electrical, fuel or mechanical failures
occur, the owner should immediately turn off the gas
supply at the manual gas valve located in the burner
compartment and electrical power to the furnace and
contact service technician.
V!'WkViVl-'! d
HAZARDOUS
GASSES!
Exposure to fuel substances, or by-products of incomplete
fuel combustion,
is believed by the state of California to
cause cancer, birth defects, or other reproductive
harm.
This warning complies with State of California law, Propo-
sition 65.
This product must be gas piped by a Licensed Plumber or
Gas Fitter in the Commonwealth
of Massachusetts.
IMPORTANT: This product has been designed and manufac-
tured to meet ENERGY STAR criteria for energy efficiency.
However, proper refrigerant
charge and proper air flow are
critical to achieve rated capacity and efficiency. Installation
of
this product should follow the manufacturer's
refrigerant
charging and air flow instructions.
Failure to confirm
proper
charge
and airflow
may reduce energy
efficiency
and
shorten equipment life.

Advertisement

loading

This manual is also suitable for:

4yc**018a2yc**018a2yc**024a4yc**024a2yc**030a4yc**030a ... Show all