Batteryservice - Snapper P2167519B (7800218 Safety Instructions & Operator's Manual

21" steel deck walk mowers series 19
Hide thumbs Also See for P2167519B (7800218:
Table of Contents

Advertisement

Maintenance(Continued)
BatteryService
New BatteryPreparation
1. Remove the battery from the carton.
2. Placethe battery in a well ventilated area on a level non-
concrete surface.
3. Remove the battery cell caps. Fill the cells as required
with electrolyte (supplied with battery) to the proper
level. Filling the battery with electrolyte will bring the
battery to 80% charged state.
4. With the cell caps removed, connect the battery charger
to the battery terminals; REDto positive (+) and BLACK
to negative (-) terminal.
IMPORTANT:Never place anything in the battery other than
the specified electrolyte.
5. Slow charge the battery at 1 amp for 2 hours to bring
the battery to full charge.
6. After charging, check the level of electrolyte and add as
needed to bring to the proper fluid level.
7. Reinstall the cell caps.
8. Install the battery into the power unit.
9. Connect the positive (+) cable (red) first, from the wiring
harness to the positive terminal (+) on the battery using
the bolt and nut provided in the hardware bag. Connect
the negative (-) cable (black) last, to the negative termi-
nal (-) on the battery using the bolt and nut. Apply a
small amount of grease over the terminals to prevent
corrosion.
WARNING
DONOToverfill batterywith electrolyte.Shieldthe positive
terminalwith terminalcoverlocatedon batteryharness.This
preventsmetalfrom touchingthe positiveterminal,which could
cause sparks.Theelectrolyte (acid)produces a highlyexplosive
gas.Keep all sparks,flameandfire awayfrom areawhen
chargingbatteryor whenhandling electrolyte or battery.
Electrolyte (acid)is a highlycorrosiveliquid.Weareyeprotection.
Washaffected areasimmediately after havingeyeor skin contact
with electrolyte (acid).Batteryacid is corrosive.Rinseemptyacid
containers with waterand mutilatebeforediscarding.If acidis
spilledon battery,bench, o r clothing,etc.,Flushwith clearwater
and neutralize with bakingsoda.Never attemptto chargebattery
while installed on the walk behind.Neveruse"BOOST" c hargers
on the battery.
BatteryService
1. Removethe battery.
2. Place the battery in a well ventilated area on a level sur-
face.
3. Using distilled water, refill the cells as required to cover
the cell plates.
4. With the cell caps removed, connect the battery charger
to the battery terminals. Redto positive (+) terminal
and black to negative (-) terminal.
5. Slow charge the battery at 1 amp for 10 hours.
6. If the battery will not accept a charge or is partially
charged after 10 hours of charging at 1 amp, replace
with a new battery.
BatteryStorage
If the Walk Behind is to be stored out of season on its rear
bumper, it is recommendedthe battery be removed, charged
and stored.
1. Removethe battery.
2. Perform battery service.
3. Bring the battery to full charge, if required.
4. Store the battery in an area away from the Walk Behind
on a wood surface. DO NOT STOREBATTERY ON A
CONCRETE SURFACE.
Battery Testing
There are two types of battery tests: Unloaded and Loaded.
The unloaded test is the procedure that will be discussed. It's
the simplest and most commonly used. An unloaded test is
made on a battery without discharging current. To perform
unloaded testing, check charge condition using either a
hydrometer or voltmeter.
.
.
Using a voltmeter, voltage readings appear instantly to
show the state of charge. Rememberto hook the posi-
tive lead to the battery's positive terminal, and the nega-
tive lead to the negative terminal.
A hydrometer measuresthe specific gravity of each cell.
The specific gravity tells the degree of charge; generally,
a specific gravity of about 1.265 to 1.280 indicates full
charge. A reading of 1.230 to 1.260 indicates the battery
should be charged. The chart below shows the charge
level as measured by syringe float hydrometer, digital
voltmeter and five ball hydrometer.
Methodsof CheckingBattery Condition
State of Charge
Syringe Hydrometer
Digital Voltmeter
Five Ball Hydrometer
100% Chargedw/Sulfate Stop
1.280
12.80v
Five Balls Floating
100% Charged
1.265
12.60v
Four Balls Floating
75% Charged
1.210
12.40v
Three Balls Floating
50% Charged
1.160
12.10v
Two Balls Floating
25% Charged
1.120
11.90v
One Ball Floating
0% Charged
Less than 1.100
Less than 11.80v
Zero Balls Floating
m,